Checks and limit profiles

Every threshold lives in a profile you can edit and export.

Limits

No check has a number written into it. Timeouts, voltage windows, attenuation and CAN periods come from the active limit profile. Open Limits in the top bar (Expert mode) to change a value; the session is checked again at once.

Values marked verify come from secondary sources or lab practice and have not been checked against the edition of the standard you test to.

Shipped profiles

Limits lists the values still to check against the standard, grouped by the document that settles them. When you have checked one, use Mark as checked with the clause or table and your name: the VERIFY flag comes off and the entry keeps who checked it, when and against what. Export the profile to keep the record.

Three profiles ship: the IEC 61851-1 and ISO 15118-2 defaults, SAE J1772 and J3400 for North America, which changes only what J1772 sets differently, and Open-RTH for the remote test harness of that name. Below the verdict the analyzer says which profile the checks used. When the EVSEID or the supply voltage points to North America it suggests the SAE profile, and one click checks the session with it. In Limits, start from any of them and edit from there.

Open-RTH relays the messages between a car and a charger at two sites but no power, so every session stops at or before pre-charge, and the relay adds 1 to 3 s to every answer. Its profile sets rig.stopsBeforeEnergy: a session that stops before the energy transfer with no refusal and no error before it then reads Stopped before energy by design instead of a failure, and the errors from the stop on are named as the rig's. It also adds 3 s to the message timeouts. Set rig.stopsBeforeEnergy to 1 in a profile of your own for another rig that works the same way.

Which checks run

A session only runs the checks of the standard on the wire: a CHAdeMO log is not asked about SLAC. The Checks tab of a session lists every check that ran with pass, fail or not applicable and the reason.