Why a charging curve looks the way it does

How the battery, not the charger, shapes most of a DC charging curve: constant current and constant voltage, tapering with state of charge, temperature, and the 400 V against 800 V question, and how to read it in a capture.

Constant current, then constant voltage

A lithium ion cell is charged with a current limit until its voltage reaches the maximum the cell chemistry allows (about 4.2 V for common NMC cells, about 3.65 V for LFP), then at that voltage with a current that falls on its own. A pack is many cells in series: about 96 for a nominal 400 V pack, about 192 for 800 V. The BMS watches the highest cell, so one weak cell can end the fast part early.

Real cars do not use a single current step. The BMS holds a table of permitted current by state of charge and temperature and walks down it as the cells fill, which gives the stepped taper seen in most curves.

Tapering with state of charge

SOC rangeTypical behaviour on a DC fast charger
0 to 10 %Current rises to the peak; some cars start lower while cell voltages are very low
10 to 50 %Peak current. The limit is often the charger, the cable or the battery temperature rather than the cells
50 to 80 %Stepwise reduction as the highest cell nears its voltage limit
80 to 100 %Near constant voltage; current falls steeply. The last 20 % can take as long as 10 to 80 %

These are general patterns; every car and cell type differs. LFP packs have a flat voltage curve and often hold high current longer, then fall off sharply.

On AC the curve is flat almost to the end: the onboard charger, the duty cycle or the cable limits the power long before the cells do, and only the last few percent taper.

Temperature and preconditioning

  • Cold cells accept little current: charging them fast risks lithium plating on the anode, so the BMS limits current until the pack warms up.
  • Hot cells are limited too, to slow ageing; a second fast charge after a long motorway drive is often slower than the first.
  • Preconditioning: many cars heat or cool the pack on the way to a fast charger, typically when the charger is the navigation destination, so the peak current is available on arrival.
  • In a capture, a temperature limit shows as a low EVTargetCurrent at low state of charge that rises during the session while the voltage barely changes.

400 V and 800 V

Power is voltage times current. Cable and connector limit the current, so an 800 V pack gets twice the power through the same 500 A cable. The charger's power modules have a voltage range and a current limit, and many also a power limit, which shapes the curve:

SituationWhat limitsWhat the curve shows
400 V car on a high power chargerCharger or cable currentFlat current at the charger limit, power rising slowly with pack voltage
800 V car on a 920 or 1 000 V chargerBatteryHigh power; the car's own taper dominates
800 V car on an older 500 V chargerVoltage range of the chargerNeeds a boost converter in the car, or cannot charge at all
Charger in constant powerCharger powerCurrent falls slowly as pack voltage rises: I = P / U. This is not the car tapering
Shared cabinet with two carsPower split between outletsA step down when the second car starts

Cars built for 800 V that must also charge at 400 V chargers step the voltage up on board, either with a separate DC/DC converter or by using the drive inverter and motor windings as a boost stage. Charging through a boost stage is usually slower than native 800 V charging.

Reading the curve in a capture

ProtocolCar asks forCharger deliversCharger limit flags
DIN SPEC 70121, ISO 15118-2EVTargetCurrent, EVTargetVoltage in CurrentDemandReqEVSEPresentCurrent, EVSEPresentVoltage in CurrentDemandResEVSECurrentLimitAchieved, EVSEVoltageLimitAchieved, EVSEPowerLimitAchieved
ISO 15118-20 DC, scheduledEVTargetCurrent, EVTargetVoltage in DC_ChargeLoopReqEVSEPresentCurrent, EVSEPresentVoltage in DC_ChargeLoopResthe same three flags
ISO 15118-20 DC, dynamicLimits only (EVMaximumChargePower and similar); the charger sets the operating pointEVSEPresentCurrentthe same three flags
CHAdeMOcurrent request in 0x102present current in 0x109available current in 0x108
GB/T 27930demand in BCLoutput in CCSmaximum output in CML
  • Present current follows the target down: the car is tapering. Nothing is wrong with the charger.
  • Present current stays below the target with a limit flag set: the charger is the limit. Check EVSEMaximumCurrentLimit and EVSEMaximumPowerLimit in the same responses.
  • Present current above the target for more than a moment: the charger overshoots. IS20-04 checks this for ISO 15118-20 in scheduled mode; in dynamic mode the target is not a limit and the check does not apply.
  • Measured current from a log above the permitted current: PW-01, which takes the smallest of all limits in force.

The troubleshooting page on slow charging walks through these cases starting from the symptom.

Sources

  • ISO 15118-2:2014 and DIN SPEC 70121:2014-12, CurrentDemandReq and CurrentDemandRes
  • ISO 15118-20:2022, DC_ChargeLoopReq and DC_ChargeLoopRes
  • CHAdeMO specification and GB/T 27930, current request and output messages