DIN SPEC 70121: DC charging, the early CCS protocol
The DC only predecessor of ISO 15118-2, still spoken by most CCS cars and chargers in the field. External identification only, normally without TLS.
In practice
- DC only. Namespace urn:din:70121:2012:MsgDef, VersionNumberMajor 2.
- Payment is ExternalPayment; there is no Plug and Charge. The SDP request normally asks for no TLS.
- Messages: SessionSetup, ServiceDiscovery, ServicePaymentSelection, ContractAuthentication, ChargeParameterDiscovery, CableCheck, PreCharge, PowerDelivery, CurrentDemand, WeldingDetection, SessionStop.
- A car that offers both DIN and ISO 15118-2 lists them with different priorities; the charger picks the highest priority it supports.
Most of the public pyPLC field captures the tool is validated on are DIN SPEC 70121 sessions with real cars and chargers.
Typical failures seen in the field
- CableCheck ending with FAILED because the insulation check found a fault or timed out.
- The charger dropping the TCP connection in the middle of the CurrentDemand loop, reported as Connection lost.
- PreCharge not reaching the target voltage in time, after which the car stops.
Sources
- DIN SPEC 70121:2014-12