IEC 61851-1: the Control Pilot
The analogue signal every conductive charger speaks: states A to F as voltage levels, and a 1 kHz PWM whose duty cycle announces the available current or asks for digital communication.
States
| State | High level | Meaning |
|---|---|---|
| A | +12 V | No car connected |
| B | +9 V | Car connected, not ready for energy |
| C | +6 V | Car ready, energy transfer allowed |
| D | +3 V | As C, with ventilation required |
| E | 0 V | Short circuit or charger fault |
| F | -12 V | Charger not available |
The car moves between B and C by switching a resistor. The charger switches between A, B, E and F. The low level of the PWM is -12 V in every state with PWM.
The voltage windows the tool accepts are those of IEC 61851-1:2017 Table A.4, kept in the limit profile so a lab can change them for another edition.
Duty cycle
What the car may draw for each duty cycle, after IEC 61851-1:2017 Table A.8. The charger generates 980 Hz to 1 020 Hz (Table A.2); the car accepts 1 kHz plus or minus 5 percent. In three phase systems the value is per phase, and with digital communication the lower of the PWM and the digital value applies.
| Duty cycle | Meaning |
|---|---|
| below 3 % | No current may be drawn |
| 5 % (3 % to 7 %) | Digital communication required (ISO 15118 or DIN 70121) |
| above 7 % and below 8 % | No current may be drawn |
| 8 % to below 10 % | 6 A |
| 10 % to 85 % | Available current = duty cycle x 0.6 A |
| above 85 % to 96 % | Available current = (duty cycle - 64) x 2.5 A |
| above 96 % to 97 % | 80 A |
| above 97 % | No current may be drawn |
Combined with ISO 15118-3
- CP-04: the 5 % duty cycle comes before SLAC starts.
- CP-05: if no SLAC starts within TT_EVSE_SLAC_init, the charger goes to E or F for a short time and back to 5 %, which wakes the car for a retry.
- CP-06: a change from 5 % to a nominal duty cycle after communication started passes through state X1 (no PWM).
- CP-07 and CP-08: the car switches B to C within 250 ms of PowerDeliveryReq Start, and back to B after PowerDelivery Stop.
Sources
- IEC 61851-1:2017, Tables A.2, A.4, A.6, A.8 and B.2