IEC 61851-1: the Control Pilot

The analogue signal every conductive charger speaks: states A to F as voltage levels, and a 1 kHz PWM whose duty cycle announces the available current or asks for digital communication.

States

StateHigh levelMeaning
A+12 VNo car connected
B+9 VCar connected, not ready for energy
C+6 VCar ready, energy transfer allowed
D+3 VAs C, with ventilation required
E0 VShort circuit or charger fault
F-12 VCharger not available

The car moves between B and C by switching a resistor. The charger switches between A, B, E and F. The low level of the PWM is -12 V in every state with PWM.

The voltage windows the tool accepts are those of IEC 61851-1:2017 Table A.4, kept in the limit profile so a lab can change them for another edition.

Duty cycle

What the car may draw for each duty cycle, after IEC 61851-1:2017 Table A.8. The charger generates 980 Hz to 1 020 Hz (Table A.2); the car accepts 1 kHz plus or minus 5 percent. In three phase systems the value is per phase, and with digital communication the lower of the PWM and the digital value applies.

Duty cycleMeaning
below 3 %No current may be drawn
5 % (3 % to 7 %)Digital communication required (ISO 15118 or DIN 70121)
above 7 % and below 8 %No current may be drawn
8 % to below 10 %6 A
10 % to 85 %Available current = duty cycle x 0.6 A
above 85 % to 96 %Available current = (duty cycle - 64) x 2.5 A
above 96 % to 97 %80 A
above 97 %No current may be drawn

Combined with ISO 15118-3

  • CP-04: the 5 % duty cycle comes before SLAC starts.
  • CP-05: if no SLAC starts within TT_EVSE_SLAC_init, the charger goes to E or F for a short time and back to 5 %, which wakes the car for a retry.
  • CP-06: a change from 5 % to a nominal duty cycle after communication started passes through state X1 (no PWM).
  • CP-07 and CP-08: the car switches B to C within 250 ms of PowerDeliveryReq Start, and back to B after PowerDelivery Stop.

Sources

  • IEC 61851-1:2017, Tables A.2, A.4, A.6, A.8 and B.2