ISO 15118-20: control modes, BPT and power profiles

Scheduled and dynamic control, bidirectional power transfer for vehicle to home and vehicle to grid, asymmetric AC and what Amendment 1 adds.

Scheduled control mode

  • The charger offers schedules in ScheduleExchangeRes. Unlike ISO 15118-2 they carry target power, not maximum power.
  • The car checks whether it can follow a schedule, which needs a forecast of its state of charge, battery temperature and auxiliary loads, and commits to an EVPowerProfile in PowerDeliveryReq.
  • Fully populated schedule tables can need up to 2 MB of memory in the car, so implementations limit their sizes.
  • Suited to planned use: an aggregator combines many cars into a virtual power plant and plans a day ahead (vehicle to grid).

Dynamic control mode

  • The charger sets the power during the charge loop.
  • It takes the mobility needs into account: departure time and target state of charge, provided either by the car or by the charger (MobilityNeedsMode EVCC or SECC).
  • Suited to hard to predict loads such as a home with photovoltaics (vehicle to home).

IS20-02 checks that the control mode does not change during a session.

Bidirectional power transfer

Use caseWhereTypical control
Vehicle to loadOff grid, supplies a deviceNot in scope of the grid codes
Vehicle to homeBehind the meter: backup power, PV self consumption, peak shavingDynamic, mobility needs from the charger
Vehicle to gridIn front of the meter: spot market, grid supportScheduled, mobility needs from the car

In ISO 15118-20 as published, bidirectional transfer is specified for DC (DC_BPT). AC_BPT exists as a service; AC bidirectional operation with grid codes arrives with Amendment 1.

IS20-05 checks that power only flows back to the grid in a session that selected a BPT service.

Asymmetric AC

A car asks for different power per phase by sending the _L2 and _L3 elements (for example EVMaximumChargePower_L2). That is useful for vehicle to home, where loads sit on individual phases, and not needed for vehicle to grid, where aggregation smooths them out.

The standard does not say what happens when the charger does not support asymmetric values: there is no handshake for it. IS20-10 reports such a session as information, not as a fault of either side.

Amendment 1: AC_DER

Amendment 1 adds a service AC_DER for AC bidirectional transfer: the charger sends the grid code to the car, the car activates the matching functions for its region, and it reports its system configuration such as the inverter model. It was at FDIS stage in early 2025.

The EXI codec in this tool does not include the Amendment 1 schema yet, so AC_DER messages are not decoded.

Sources

  • ISO 15118-20:2022, energy transfer services and control modes