ISO 15118-3: powerline communication and SLAC
HomePlug Green PHY on the Control Pilot wire, and the SLAC procedure that pairs the car's modem with the right charger before any IP traffic flows.
Why SLAC
Powerline signals cross between neighbouring cables, so a car could hear several chargers. Signal Level Attenuation Characterization measures the attenuation to every charger modem that answers and joins the logical network of the one with the strongest signal, which is the one it is plugged into.
The sequence
- EV: CM_SLAC_PARM.REQ, broadcast, carries the RunID of this attempt
- EVSE: CM_SLAC_PARM.CNF, from every charger that hears it
- EV: CM_START_ATTEN_CHAR.IND, three times
- EV: CM_MNBC_SOUND.IND, the sounding, normally 10 times
- EVSE: CM_ATTEN_PROFILE.IND, modem to host, per sound
- EVSE: CM_ATTEN_CHAR.IND, attenuation per carrier group
- EV: CM_ATTEN_CHAR.RSP
- EV: CM_SLAC_MATCH.REQ, to the charger with the lowest attenuation
- EVSE: CM_SLAC_MATCH.CNF, network ID and key; the car's modem joins
SL-01 checks the sequence is complete, SL-02 that the RunID stays the same, SL-03 the number of sounds, SL-04 their spacing, SL-05 the time to CM_ATTEN_CHAR.IND and SL-06 the attenuation.
Timers and thresholds
| Value | Profile default |
|---|---|
| Spacing of the sound messages | 20 to 50 ms |
| TT_EV_atten_results, first START_ATTEN_CHAR to ATTEN_CHAR.IND | 1200 ms |
| TT_EVSE_SLAC_init, charger waits for SLAC before it retries | 20 to 50 s |
| Average attenuation a lab accepts | 40 dB |
The attenuation threshold is lab practice rather than a value from the standard, and the timers are marked for verification.
Reading a SLAC failure
The sequence is fixed, so the last message in the capture says who owed the next one. The verdict names that side. For example a charger that answered CM_SLAC_PARM.REQ three times and then heard nothing was waiting for the car.
Sources
- ISO 15118-3:2015, SLAC timing and message set as cited in the text