ISO 15118-3: powerline communication and SLAC

HomePlug Green PHY on the Control Pilot wire, and the SLAC procedure that pairs the car's modem with the right charger before any IP traffic flows.

Why SLAC

Powerline signals cross between neighbouring cables, so a car could hear several chargers. Signal Level Attenuation Characterization measures the attenuation to every charger modem that answers and joins the logical network of the one with the strongest signal, which is the one it is plugged into.

The sequence

  1. EV: CM_SLAC_PARM.REQ, broadcast, carries the RunID of this attempt
  2. EVSE: CM_SLAC_PARM.CNF, from every charger that hears it
  3. EV: CM_START_ATTEN_CHAR.IND, three times
  4. EV: CM_MNBC_SOUND.IND, the sounding, normally 10 times
  5. EVSE: CM_ATTEN_PROFILE.IND, modem to host, per sound
  6. EVSE: CM_ATTEN_CHAR.IND, attenuation per carrier group
  7. EV: CM_ATTEN_CHAR.RSP
  8. EV: CM_SLAC_MATCH.REQ, to the charger with the lowest attenuation
  9. EVSE: CM_SLAC_MATCH.CNF, network ID and key; the car's modem joins

SL-01 checks the sequence is complete, SL-02 that the RunID stays the same, SL-03 the number of sounds, SL-04 their spacing, SL-05 the time to CM_ATTEN_CHAR.IND and SL-06 the attenuation.

Timers and thresholds

ValueProfile default
Spacing of the sound messages20 to 50 ms
TT_EV_atten_results, first START_ATTEN_CHAR to ATTEN_CHAR.IND1200 ms
TT_EVSE_SLAC_init, charger waits for SLAC before it retries20 to 50 s
Average attenuation a lab accepts40 dB

The attenuation threshold is lab practice rather than a value from the standard, and the timers are marked for verification.

Reading a SLAC failure

The sequence is fixed, so the last message in the capture says who owed the next one. The verdict names that side. For example a charger that answered CM_SLAC_PARM.REQ three times and then heard nothing was waiting for the car.

Sources

  • ISO 15118-3:2015, SLAC timing and message set as cited in the text