SAE J1939 on a charging bus

How 29 bit identifiers, PGNs and the broadcast transport protocol carry GB/T 27930 messages longer than eight bytes.

Identifiers

A 29 bit identifier holds priority, the parameter group number (PGN) and source and destination addresses. In GB/T 27930 the charger is address 0x56 and the BMS 0xF4.

Broadcast transport

  • A message longer than eight bytes is announced with TP.CM (BAM) giving its size, packet count and PGN.
  • The data follows in TP.DT packets of seven bytes each, numbered from 1.
  • The decoder only completes a message when every packet arrived, rejects announcements whose packet count does not fit the size, and ignores packets outside the announced range.

Sources

  • SAE J1939-21, transport protocol