SAE J1772: the North American coupler and pilot

The SAE standard for the Type 1 AC coupler, the CCS1 combo coupler and the Control Pilot that goes with them. The pilot is the same 1 kHz PWM signal as in IEC 61851-1; the charging levels and the proximity circuit are specific to North America.

What it defines

  • The Type 1 coupler: five contacts (two power contacts L1 and L2/N, protective earth, Control Pilot, Proximity). IEC 62196-2 lists it as Type 1.
  • The combo coupler that adds two DC contacts below the Type 1 face, known as CCS1 or Combo 1 and listed in IEC 62196-3 as configuration EE.
  • The Control Pilot circuit, states and duty cycle rules, harmonised with IEC 61851-1: 1 kHz, plus and minus 12 V, states A to F, 5 percent duty for digital communication.
  • The proximity circuit with the latch switch, and the charging levels.

For the high level communication J1772 points to the SAE J2931 documents for powerline (HomePlug Green PHY, as in ISO 15118-3) and to SAE J2847/2 for the DC messages. In practice North American CCS1 chargers speak DIN SPEC 70121 and ISO 15118-2, and increasingly ISO 15118-20.

The revision history (the 2010 revision introducing today's coupler, the 2012 revision adding the combo coupler) and the J2931 part numbers are to be verified against the SAE catalogue.

Charging levels

LevelSupplyCurrentTypical use
AC Level 1120 V single phaseup to 16 APortable cord set on a household outlet
AC Level 2208 V to 240 V single phaseup to 80 AWall box and public AC charger
DC Level 1DC from an off-board chargerup to 80 AEarly low power DC
DC Level 2DC from an off-board chargerup to 200 A in early revisions, higher laterPublic DC fast charging over CCS1

The DC level voltage ranges and current limits changed between revisions. Treat the DC rows as orientation and verify them against the revision you test to. The terms "Level 3" and "DC fast charging" are colloquial, not J1772 levels.

North American AC is single phase (or split phase); J1772 has no three phase AC. A duty cycle that announces more than 80 A therefore does not occur on Type 1.

Control Pilot: same signal, same checks

The pilot generator in the charger, the resistor and diode in the car and the state voltages are the same as in IEC 61851-1, as is the duty cycle to current mapping (0.6 A per percent from 10 to 85 percent duty). A CP log from a J1772 charger is therefore analysed with the same CP checks, CP-01 to CP-10, and the same limit profile. Two practical differences:

  • Residual current protection in North America is a charge circuit interrupting device (CCID) in the charger, with its own trip levels, instead of an RCD in the installation.
  • Many North American cord sets and wall boxes use a lower nominal current than the cable could carry, so a duty cycle of 20 percent (12 A) or 26.7 percent (16 A) is common on Level 1.

Proximity and the latch

The Type 1 connector has a latch with a release button. The proximity circuit is a resistor network between PP and earth in the connector, with a switch coupled to the button. The car sees one voltage on PP when the connector is inserted and latched, and a different one when the button is pressed. A car should reduce current to zero before the connector is unlatched and pulled, which avoids arcing at the contacts.

Commonly quoted values are 150 ohm with the latch closed and 150 plus 330 ohm with the button pressed. Verify them against the proximity circuit figure of J1772 before using them as test limits.

Unlike Type 2, the Type 1 proximity resistor does not code a cable current rating: the cable is always fixed to the charger (case C), so the charger knows its own cable.

Sources

  • SAE J1772, conductive charge coupler, 2010 and later revisions
  • IEC 61851-1:2017, the harmonised Control Pilot
  • IEC 62196-2 and -3, Type 1 and configuration EE