A CHAdeMO or GB/T session stops
Reading a CAN log of a DC session that failed: which side is on the bus, the fault and stop flags, the step that timed out and the stop reason each side reported.
What you see
- A CAN log where the session never reaches charging, or where current stops before the car is full.
- The verdict comes from the protocol module. CHAdeMO categories: One side is missing, Battery incompatibility, Vehicle fault, Vehicle left park, Charger fault, No current delivered, Vehicle never allowed charging, Stopped without a normal stop request. GB/T categories: No handshake, Handshake failure, Vehicle error message, Charger error message, Vehicle stopped, Charger stopped, Vehicle fault, Charger fault, Charger never became ready, No current delivered.
CHAdeMO
| Signal | From | Check |
|---|---|---|
| No frames from one side (0x100 to 0x102 from the car, 0x108 and 0x109 from the charger) | The silent side | CH-01 |
| Fault flags in 0x102: battery overvoltage, undervoltage, current deviation, high temperature, voltage deviation, charging system fault | Car | CH-04; verdict Vehicle fault |
| Flags in 0x109: charger malfunction, battery incompatibility, charging system malfunction | Charger | CH-04; verdict Charger fault or Battery incompatibility |
| Output current above the request in 0x102 | Charger | CH-02 |
| Output voltage above the battery maximum in 0x100 | Charger | CH-03 |
| Current while the car's charging enabled flag is clear | Charger | CH-05 |
| Different control protocol numbers | Either | CH-06 |
A normal end shows the car's normal stop request flag or the charger's stop control flag. When current stops with neither, the verdict is Stopped without a normal stop request. The cause is then often on the analogue lines (charge sequence signals and the charge permission contact), which a CAN log does not show: log them on a scope next to the bus.
GB/T 27930
| Signal | Who | Check |
|---|---|---|
| CHM repeated, no BHM | BMS | GB-01; verdict Handshake failure |
| CRM repeated, no BRM | BMS | GB-02 |
| BCP without CML | Charger | GB-03 |
| BRO ready without CRO ready | Charger | GB-04; verdict Charger never became ready |
| BEM: the BMS reports which charger message it did not receive in time | Points at the charger | Verdict Vehicle error message |
| CEM: the charger reports which BMS message it did not receive in time | Points at the BMS | Verdict Charger error message |
| BST or CST with a stop reason (target reached, fault, insulation, temperature, connector) | The sender | Verdict Vehicle stopped, Charger stopped or a fault |
| Output current above the BCL demand | Charger | GB-05 |
| Measured voltage above the BMS maximum | Charger | GB-06 |
| No BST or CST, or no statistics afterwards | Either | GB-07 |
BEM and CEM are the key to a GB/T failure: the side that sends one is reporting the other side's silence. The code dictionary lists the stop reasons, faults and timeout reports.
Bus level problems
- CAN-01 reports gaps where the bus falls silent during a session, CAN-02 cyclic messages that drift from their period or stall.
- Periods that wander are often gateway jitter in the logger rather than a fault; the tolerance in the profile is wide for that reason.
- Check the bit rate (CHAdeMO runs at 500 kbit/s, GB/T 27930 commonly at 250 kbit/s) and the termination when frames are missing from one side only.
The CHAdeMO and GB/T timing and margin values in the limit profile are all flagged for verification, and the CHAdeMO byte offsets come from secondary sources.