DC session stalls in CableCheck or PreCharge
A DC session that negotiates fine but never reaches PowerDelivery Start: the insulation check never finishes or fails, or the charger cannot bring its output to the battery voltage.
What you see
- ChargeParameterDiscovery is done, then CableCheckReq and CableCheckRes repeat with EVSEProcessing Ongoing, or PreChargeReq and PreChargeRes repeat, and the session ends before PowerDelivery Start.
- The stage strip stops at Parameters, because energy transfer starts only with PowerDelivery Start.
- The verdict is Pre-charge failed when the car ends the session in pre-charge, otherwise FAILED response (for example CableCheck refused), Timeout or EV stopped early.
What the two steps do
- CableCheck: the car has locked the connector and switched to state C. The charger puts a test voltage on the cable and its insulation monitor measures the resistance to protective earth. It answers Ongoing until it is done, then Finished with EVSEIsolationStatus Valid (or Warning), and brings the voltage back down.
- PreCharge: the car sends its battery voltage as EVTargetVoltage with a small EVTargetCurrent. The charger raises its output to match. When the difference is small enough, the car closes its contactors and sends PowerDelivery Start.
- The messages come from ISO 15118-2 and DIN SPEC 70121. What the charger does electrically (insulation monitoring, the precharge current, voltage limits) is set by IEC 61851-23.
Likely causes
| Cause | Who | How to confirm in the capture |
|---|---|---|
| The car is still in state B, and the charger will not apply the test voltage without state C | EV | The CP state lane shows B during the whole CableCheck loop, which stays Ongoing |
| Insulation fault or warning: a wet connector, a damaged cable, high capacitance to earth on the car side | Either | EVSEIsolationStatus Fault or Warning in the responses; DC_EVSEStatusCode EVSE_IsolationMonitoringActive while it measures |
| Two insulation monitors active at once (the car's and the charger's) disturbing each other | Either | A warning or fault with this car only, on a charger that passes with others |
| The charger cannot reach the battery voltage, or cannot regulate a small current at that voltage | EVSE | EVSEPresentVoltage in PreChargeRes levels off below EVTargetVoltage |
| Voltage tolerance: the charger settles a few volts away from the target, and the car waits for a closer match | Either | Compare EVSEPresentVoltage with EVTargetVoltage in every PreChargeRes |
| The car's target does not match its real battery voltage (sensor offset) | EV | A precharge that ends, then a current spike or a car fault right after the contactors close |
| The loop simply takes too long and the car's timer for the step runs out | EVSE | Loop duration on the Timing tab; the car closes the connection or stops without an answer |
| Each response is slow | EVSE | TIM-01 on the CableCheck and PreCharge pairs |
What to check in this tool
- Timing tab: response time per message type, and how long each loop ran from its first request to Finished or to the end.
- Message tab of the last responses: EVSEProcessing, EVSEIsolationStatus, DC_EVSEStatusCode, EVSEPresentVoltage. The code dictionary explains the isolation status and the DC EVSE status codes.
- The CP state lane for the B to C change before CableCheck.
- DC-01 reads the last PreChargeRes: when no PowerDelivery Start follows, it reports how far the charger output was from the target (the profile allows
dc.prechargeToleranceV) and whether the loop ran pastdc.prechargeTimeoutS, and names the charger when the voltage never got close. - TIM-01 for each response and SQ-05 for a refused step. TIM-02 measures the Authorization and ChargeParameterDiscovery Ongoing loops against V2G_EVCC_Ongoing_Timeout; the CableCheck loop has its own timer, which is not in the limit profile, so compare its length by hand.
Fixes that usually work
- Car side: switch to state C before CableCheckReq and keep it there.
- Charger side: check the insulation monitor calibration and thresholds, and that it measures only while the car's own monitor is off, where the car allows that.
- Check the charger's minimum output voltage and its current regulation at low current against the battery voltage of the car under test.
- Log the charger's DC output voltage next to the capture to see whether the reported EVSEPresentVoltage is the real one.
Values often quoted and to be checked against the standards: a V2G_EVCC_CableCheck_Timeout of 40 s (not in the limit profile) and a V2G_EVCC_PreCharge_Timeout of 7 s (dc.prechargeTimeoutS, flagged) in ISO 15118-2, with DIN SPEC 70121 using slightly shorter ones; a pre-charge match within 20 V (dc.prechargeToleranceV, flagged); a precharge current of at most 2 A; and insulation levels of 100 ohm per volt (fault) and 500 ohm per volt (warning) from IEC 61851-23.
Sources
- ISO 15118-2:2014, CableCheck and PreCharge messages, timing tables
- DIN SPEC 70121:2014-12, CableCheck and PreCharge
- IEC 61851-23, DC charger requirements, insulation monitoring