Communication works but no current flows

The charging loop runs, the messages look fine, and the meter does not move: the car never switched to state C, the charger never closed its contactor, or a limit is zero.

What you see

  • PowerDelivery Start was answered OK, ChargingStatus or CurrentDemand requests repeat, and the meter reading in the responses stays the same.
  • In the Power tab (with a Control Pilot log that carries currents) the current stays at zero.

Likely causes on AC

CauseWhoHow to confirm in the capture
The car never switches to state C after PowerDeliveryReq StartEVThe CP state lane stays at B; CP-07 compares the B to C change with PowerDeliveryReq Start
The charger does not close its contactor after state CEVSEState C in the CP lane, zero current, and no phase voltage if the log has one
A current limit of zero: EVSEMaxCurrent zero or very low, or a schedule whose PMax is zeroEVSEAC_EVSEChargeParameter in ChargeParameterDiscoveryRes and the SAScheduleList
A nominal duty cycle that allows no current: the charger left the 5 percent window for a value between 7 and 8 percent, or below 3 percentEVSEDuty % lane; with digital communication the lower of the PWM value and EVSEMaxCurrent applies
The residual current device trippedEVSERCD true in the AC EVSE status
The on-board charger does not start, or draws only on a phase that is not energisedEVCurrents per phase in the Power tab

Likely causes on DC

CauseWhoHow to confirm in the capture
The car asks for no current: EVTargetCurrent zero, EVReady false (cold battery, a car fault)EVCurrentDemandReq fields
The charger does not deliver what was askedEVSEEVSEPresentCurrent near zero while EVTargetCurrent is not; DC_EVSEStatusCode other than EVSE_Ready; limit achieved flags set
A power or current limit of zero in the charger's limitsEVSEEVSEMaximumCurrentLimit and EVSEMaximumPowerLimit in the loop responses

What to check in this tool

  • CP state and Duty % lanes around PowerDelivery Start. The alignment of the Control Pilot log with the capture has to be right for CP-07 and PW-02 to mean anything.
  • Power tab: measured current and the permitted current at each moment, with the limit that binds.
  • Message tab: EVSEMaxCurrent, EVMaxCurrent, the schedule, and the status fields of the loop responses.
  • Checks: CP-07, CP-08, PW-01 to PW-03 and SQ-08.

Fixes that usually work

  • Car: confirm the software switches S2 within 250 ms of sending PowerDeliveryReq Start.
  • Charger: confirm the contactor is commanded on state C, and check its auxiliary contact and the RCD.
  • Check where the zero limit comes from: a load management setting, a backend profile or an empty schedule.
  • For a car that draws on one phase only, check which phase the charger feeds first.

The allowed delay between PowerDeliveryReq Start and the B to C change (cp.transition.maxDelayAfterPowerDeliveryS, 250 ms) is flagged for verification in the limit profile.

Sources

  • IEC 61851-1:2017, Tables A.6 and A.8
  • ISO 15118-2:2014, AC and DC charge parameters