The session does not end cleanly

Charging finished, but the end is messy: current keeps flowing after the stop, the car never opens S2, welding detection does not finish, SessionStop is missing or the connection is cut, or a pause turns into a stop.

A clean end

  1. EV: PowerDeliveryReq, ChargeProgress Stop; on DC the charger ramps down, on AC the car lowers its draw
  2. EVSE: PowerDeliveryRes
  3. EV: C to B on the Control Pilot, the car opens S2; on AC the charger then opens its contactor
  4. EV: WeldingDetectionReq, DC only, repeated while the car checks that its contactors opened
  5. EVSE: WeldingDetectionRes, EVSEPresentVoltage falling
  6. EV: SessionStopReq, ChargingSession Terminate
  7. EVSE: SessionStopRes
  8. both: TCP connection closed, after the response, by either side

The verdict reads Completed normally when SessionStop was answered and the Control Pilot then went back to B or A, or when no Control Pilot log was loaded to say otherwise. A reset that follows the closing handshake is how many stacks end a connection and does not count against TC-02.

What goes wrong

What you seeLikely causeWhoCheck
Current still flows seconds after PowerDelivery StopOn AC the car keeps drawing; on DC the charger does not ramp downEV on AC, EVSE on DCPW-03 (3 s in the profile)
The pilot stays in C after PowerDelivery StopThe car does not open S2EVCP-08
Current after the change from C to BThe charger does not open its contactor in time: 100 ms after IEC 61851-1, 3 s after SAE J1772EVSEPW-03
WeldingDetection repeats and the voltage stays highThe charger output is not discharged, it reports a stale EVSEPresentVoltage, or a contactor in the car is weldedEitherThe voltage in WeldingDetectionRes over time
The car closes the connection after PowerDelivery Stop without SessionStopThe car ends on its own timer or skips the stepEVTC-02; the verdict Connection lost or EV stopped early
SessionStopReq without a responseThe charger is already shutting its stack downEVSETIM-01, SQ-02
A pause the charger asked for ends as a stop (ISO 15118-20)The car terminated instead of pausingEVIS20-06
The capture ends before SessionStopThe recording stopped too earlyCaptureThe verdict Incomplete capture

The time the car has to stop drawing (pw.currentZeroTimeS, 3 s) and the time the charger has to open its contactor (pw.switchOpenAfterCToBS, 100 ms, 3 s in the North American profile) come from IEC 61851-1:2017 Table A.6; the North American value is flagged for verification against SAE J1772.

Welding detection and unlocking on DC

  • After PowerDelivery Stop the charger stops its output and the car opens its DC contactors. The car then repeats WeldingDetectionReq and watches EVSEPresentVoltage: with its contactors open, the voltage on the charger side should fall towards zero once the charger discharges its output.
  • If the voltage stays at battery level, the battery is still connected through a contactor that did not open. The car reports a fault and may refuse to charge again until it is serviced.
  • If the voltage falls slowly, the discharge circuit of the charger is slow or faulty, or the value in the response is not a live measurement.
  • The connector stays locked until the voltage on the cable is safe. A connector that will not unlock after a clean SessionStop usually points at a charger that still measures voltage at its output.
  • Not every car runs welding detection through the messages; some go straight from PowerDelivery Stop to SessionStop.

The voltage below which a DC connector may unlock and the time the charger has to discharge its output are set by IEC 61851-23. A commonly quoted threshold is 60 V; check it against the edition you test to. The limit profile has no value for either.

Pause and resume

  • ISO 15118-2: SessionStopReq with ChargingSession Pause keeps the SessionID. The car comes back with a SessionSetupReq carrying that SessionID, and the charger answers OK_OldSessionJoined. SQ-11 checks that the ID is reused.
  • DIN SPEC 70121 has no pause: its SessionStopReq has no fields.
  • ISO 15118-20 pauses with ChargingSession Pause in SessionStopReq, and ChargeProgress Standby in PowerDeliveryReq holds energy transfer within a session. When the charger asked for a pause, IS20-06 checks that the session ends as one.
  • A paused session looks like an ending in the capture. Read the ChargingSession field before you call it a stop.

What to check in this tool

  • The last rows of the message table, from PowerDelivery Stop on, and who sent the last message.
  • The CP state lane after PowerDelivery Stop, for the change from C to B (CP-08).
  • The Power tab, with current columns in the Control Pilot log, for current after the stop (PW-03).
  • EVSEPresentVoltage in each WeldingDetectionRes, and how fast it falls.
  • The TCP/TLS lane for who closed the connection and when, and the Capture tool for a recording that ended early.

Sources

  • ISO 15118-2:2014, PowerDelivery, WeldingDetection, SessionStop, pause and resume
  • ISO 15118-20:2022, PowerDelivery, SessionStop and pausing
  • IEC 61851-1:2017, Table A.6, sequences 7, 8.1, 9.1 and 10.1