Charging is slower than expected

The session charges, but at less power than the car or the charger is rated for. The smallest limit in force wins, and the capture says which one it was.

What you see

The session completes or keeps charging, but the current or power is lower than you expected. Before looking for a fault, work out what the expectation should have been: power is the smallest of all limits in force, and several of them are in the capture.

Where the limit comes from

LimitWhere it is in the captureCheck
PWM duty cycle (AC)Duty % lanePW-01
Cable rating from the proximity pin (AC)PP column of the Control Pilot logPP-01, PW-01
Charger maximum: EVSEMaxCurrent, EVSEMaximumCurrentLimit, EVSEMaximumPowerLimitChargeParameterDiscoveryRes and the loop responsesPW-01, IS20-03
Car maximum and request: EVMaxCurrent, EVMaximumCurrentLimit, EVTargetCurrentChargeParameterDiscoveryReq and the loop requestsPW-01, IS20-04
Power schedule: PMax per intervalSAScheduleList, or the ISO 15118-20 schedulePW-01, SQ-08
On-board charger rating and phases (AC)Currents per phase in the Power tabNone; compare with the car data
Battery: state of charge and temperatureSOC fields, EVTargetCurrent falling over timeNone; this is the charging curve
Charger derating: temperature, shared power between outlets, grid limitEVSEPresentCurrent below EVTargetCurrent, with the limit achieved flags setNone; read the flags

PW-01, IS20-03 and IS20-04 catch the opposite problem, current above a limit. A slow session passes them. The useful signal is the gap between what the car asks for and what it gets: EVTargetCurrent against EVSEPresentCurrent on DC, EVMaxCurrent against the measured current on AC.

Quick arithmetic

SetupCurrentPower
AC single phase, 230 V16 Aabout 3.7 kW
AC single phase, 230 V32 Aabout 7.4 kW
AC three phase, 230 V per phase16 A per phaseabout 11 kW
AC three phase, 230 V per phase32 A per phaseabout 22 kW
DC, 400 V battery125 A50 kW
DC, 800 V battery125 A100 kW

On DC, power is voltage times current. A charger limited to a given current delivers half the power to a 400 V battery that it delivers to an 800 V one, and a battery at low state of charge sits at a lower voltage too.

What to check in this tool

  • Power tab: measured current against the permitted current, with the name of the limit that binds at each moment.
  • Message tab of ChargeParameterDiscovery and of a few loop messages spread over the session.
  • PP-01 for a cable that codes a lower rating than expected.

Common findings

  • A 20 A or 13 A cable on a 32 A charger.
  • A single phase car on a three phase charger: only L1 carries current.
  • A schedule from the backend or load management that caps the power, often lower in the first interval.
  • A cold battery at the start of a DC session: EVTargetCurrent rises slowly as the battery warms.
  • Two cars sharing one charger's power modules.

Sources

  • IEC 61851-1:2017, Tables A.8 and B.2
  • ISO 15118-2:2014, charge parameters and SAScheduleList
  • ISO 15118-20:2022, dynamic and scheduled control