Bidirectional charging: V2G, V2H, V2L
What vehicle to load, home and grid mean, why AC and DC bidirectional charging are regulated so differently, how ISO 15118-20 and CHAdeMO carry it, and what IS20-05 checks.
Definitions
| Term | Energy goes to | Grid connected | Typical hardware |
|---|---|---|---|
| V2L (vehicle to load) | Devices plugged into the car or an adapter | No | Onboard inverter with a socket or inlet adapter |
| V2H (vehicle to home) | The household, behind the meter | Yes, or as backup in island mode | Bidirectional charger with a transfer switch |
| V2B (vehicle to building) | A commercial building, behind the meter | Yes | As V2H, larger |
| V2G (vehicle to grid) | The public grid, in front of the meter | Yes | Bidirectional charger plus an aggregator or energy market access |
V2X is the umbrella term. V2L needs no charger at all, and it is not covered by ISO 15118; cars recognise their V2L adapters by maker specific means.
AC or DC bidirectional
| DC bidirectional | AC bidirectional | |
|---|---|---|
| Where the inverter is | In the charger | In the car (the onboard charger runs backwards) |
| Who must meet the grid code | The charger, as a stationary unit | The car, which becomes a mobile generating unit |
| Charger complexity | High: a bidirectional DC charger | Low: an AC wallbox with communication |
| Grid code per country | Certified once per charger model | The car must apply the settings of wherever it is plugged in |
| ISO 15118-20 service | DC_BPT | AC_BPT, with grid code exchange through AC_DER in Amendment 1 |
That last row is the main reason DC bidirectional systems came first: certifying one stationary inverter is straightforward, while a car that feeds the grid from any AC wallbox must know and follow the rules of the country and network it is connected to.
ISO 15118-20 BPT
- EVSE: ServiceDiscoveryRes, lists DC_BPT (6) or AC_BPT (5) among the energy services
- EV: ServiceDetailReq, asks for the parameter sets of the BPT service
- EV: ServiceSelectionReq, selects the BPT service and one parameter set
- EV: DC_ChargeParameterDiscoveryReq, BPT variant with charge and discharge limits
- both: ScheduleExchange, scheduled or dynamic control
- EV: DC_ChargeLoopReq, power may now flow in either direction
- The BPT variants of the parameter messages add discharge limits for both sides, such as
EVMaximumDischargePower,EVMinimumDischargePowerandEVMaximumDischargeCurrent, and theirEVSEcounterparts. - In dynamic control the charger decides the direction and the power, within the car's limits and its mobility needs (departure time and target state of charge).
- The meter counts both directions separately:
ChargedEnergyReadingWhandBPT_DischargedEnergyReadingWhinMeterInfo. PW-04 checks that the charged energy counter never runs back; the discharged counter is not checked yet. - In ISO 15118-20 as published, bidirectional operation is specified for DC; AC bidirectional operation with a grid code exchange arrives with Amendment 1 (
AC_DER). ISO 15118-2 and DIN SPEC 70121 have no bidirectional services.
The BPT service parameters (for example the channel arrangement and grid following or grid forming operation) are described here from secondary sources; check their names and values against the service parameter tables of ISO 15118-20.
CHAdeMO V2X
CHAdeMO was the first charging system with bidirectional operation in volume: V2H units in Japan have discharged cars through the DC connector for over a decade, with the inverter in the V2H unit. The discharge is negotiated in additional CAN frames of the later protocol versions, which this tool lists but does not yet check.
The CHAdeMO version that introduced discharging, the frame identifiers used for it and the status of the V2H guideline are to be checked against the CHAdeMO specification.
Grid codes
Any unit that feeds power into the grid is a generating unit and must follow the grid connection rules of its network: frequency and voltage ranges, ride through, reactive power, and disconnection when the grid fails (anti islanding).
| Region | Rules commonly applied |
|---|---|
| Germany | VDE-AR-N 4105 for units on the low voltage grid, with unit and system certificates |
| Europe | EN 50549-1, adapted by national network operators |
| United States | IEEE 1547-2018, tested to IEEE 1547.1 and listed to UL 1741 (supplement SB); SAE J3072 for onboard inverters on AC; California Rule 21 |
Which edition applies, and how the rules treat a car that feeds back through an AC wallbox, differ by country and change over time. Check the current requirements of the network operator.
What IS20-05 checks
IS20-05 looks at the service the car selected in ServiceSelectionReq. If it is a BPT service the check passes: power may flow both ways. If it is a one directional service (DC or AC) and a charge loop message names a maximum discharge power above zero, or the charger reports a negative EVSEPresentCurrent (current flowing out of the car), the check fails. The likely party is either side: the car may announce discharge it was not granted, or the charger may draw power it has no right to.
The check needs a decoded ServiceSelectionReq; without one it reports not applicable. In the iso20 demo the charger offers DC and DC_BPT, the car selects DC, and no power flows back, so the check passes.
Sources
- ISO 15118-20:2022, services AC_BPT and DC_BPT, BPT parameters
- CHAdeMO specification, V2H guideline and bidirectional extensions
- VDE-AR-N 4105, generators in the German low voltage grid
- EN 50549-1, requirements for generating plants connected to low voltage distribution networks
- IEEE 1547-2018 and UL 1741 SB, interconnection of distributed energy resources in the US
- SAE J3072, onboard inverter systems interconnected with the grid