Depot charging for bus, van and truck fleets
Fleets that return to a depot and must leave charged on schedule: AC and DC chargers under a charge management system, OCPP charging profiles, ISO 15118 for identification, departure time and preconditioning, telematics for the state of charge, pantographs for buses under SAE J3105, and what transit agencies report going wrong.
The setting
Buses, delivery vans and trucks come back to a yard, charge overnight or between shifts, and must be ready at a planned departure time. The depot operator runs a charge management system that knows the vehicles, the timetable and the grid connection. Involved are the fleet operator, the charge point operator (often the same company), the vehicle makers, the depot or intermodal transport control system, and the network operator. Depots use AC wallboxes, DC chargers (sometimes dispensers sharing a power cabinet) and, for buses, pantographs.
Scheduled charging with OCPP
- The charge management system sends limits to each charger with OCPP. In OCPP 2.0.1 a profile has a purpose:
ChargingStationMaxProfilecaps the whole station,TxDefaultProfileapplies to every transaction,TxProfileto one running transaction, andChargingStationExternalConstraintsreports limits set by something outside the backend. - Within one purpose the profile with the highest stack level wins; across purposes the station applies the lowest limit in force, so a TxProfile can go below the site cap but never above it.
- A fleet schedule is therefore a TxProfile per vehicle, recomputed when a bus arrives late or the grid limit changes. The charger turns it into a duty cycle on AC, or into the limits it sends the car on DC.
The profile rules above follow OCPP 2.0.1; OCPP 1.6 has the same idea with its own names and fewer purposes. The OCPP: the charger's link to its backend page covers both editions.
What the vehicle tells the depot
| Link | Identity | State of charge | Departure time and energy |
|---|---|---|---|
| Control Pilot only (AC) | None | None | None |
| DIN SPEC 70121 or ISO 15118-2 DC | EVCCID (the MAC address of the modem) | Yes: EVRESSSOC in the DC status of the car | ISO 15118-2 only, optional: DepartureTime, EVEnergyRequest |
| ISO 15118-2 AC | EVCCID; a contract certificate with Plug and Charge | No: the AC parameters carry DepartureTime and EAmount only | Yes, with the departure time optional |
| ISO 15118-20 AC or DC | EVCCID; contract certificate with PnC | Optional, in DisplayParameters (PresentSOC) of the charge loop | Yes, and the charger may control dynamically |
- Without a state of charge on the cable, depots read it from the vehicle telematics and match the vehicle to the charger by the depot plan. That match is where many depot problems start.
- Autocharge uses the
EVCCIDfrom DIN SPEC 70121 or ISO 15118 as an identifier and sends it to the backend in an OCPP Authorize; published Autocharge material names operators in the Netherlands, France, Austria, Norway and Switzerland that used it. It is not a secure identity: a MAC address can be copied. Plug and Charge and its PKI explains the certificate based alternative. - German public transport uses two VDV recommendations on top: VDV 261 for preconditioning (heating or cooling the bus from the grid before departure) through the value added services of ISO 15118, and VDV 463 for the exchange between the charge management and the depot and transport control systems.
Pantographs for buses
SAE J3105 (first issued January 2020, revised May 2023) covers DC power transfer through an automated connection device. Three parts define the interfaces: J3105/1 an infrastructure mounted pantograph that comes down onto rails on the roof of the bus, J3105/2 a pantograph mounted on the vehicle that goes up to an overhead contact, and J3105/3 an enclosed pin and socket connection.
OppCharge is the commercial name of the infrastructure mounted variant, led by Volvo Buses with other makers. The ABB leaflet for its pantograph charger lists 150, 300, 450 and 600 kW, charging per IEC 61851-23 with DIN SPEC 70121 and ISO 15118, and pairing between bus and charger over WLAN (IEEE 802.11n) as the bus approaches, since there is no cable to carry powerline communication before contact.
How ISO 15118 runs over WLAN for pantographs (ISO 15118-8 names wireless communication) is not decoded by this tool: it reads powerline and Ethernet captures.
What transit agencies report
- Timing of the build out. NREL reported for Foothill Transit that buses were delivered from 2017 but full service only started in early 2020, because the chargers were not ready.
- Charger faults with consequences for service: the same NREL report describes arcing that started fires at on-route chargers in May and October 2020, after which the agency ran the routes with CNG buses until repairs were done.
- Mixed fleets. The FTA guidebooks of August 2023 warn that agencies buying buses from more than one maker must make sure chargers and buses are interoperable, or depot space runs out; they also report that agencies doubted charge management software would integrate with their fleet and scheduling systems, and that spare parts became hard to find when a charger maker dropped its product line.
What to record and test
- Per vehicle model and charger model: a complete session with the network capture, the OCPP log of the charger, and the telematics state of charge for the same minutes.
- Schedule tests: a TxProfile sent before the car plugs in, a profile changed during charging, a ChargingStationMaxProfile lowered below the running sessions, and a backend that goes offline mid session (the charger should fall back to its default).
- ISO 15118 tests: departure time and energy request as the car sends them, a renegotiation started by the charger, and the preconditioning service if the fleet uses VDV 261.
- DC test cases, worked and Backend, Plug and Charge and payment test cases give test case forms for these.
In this tool
- The iso20 demo shows an ISO 15118-20 DC session in scheduled control mode; the Negotiation tool lists what car and charger announced side by side, the Curve tool the target against the delivered current and power.
- SQ-08 checks that PowerDelivery uses a schedule tuple the charger sent, SQ-09 that the car reacts to an EVSENotification in time, IS20-09 that an ISO 15118-20 schedule renegotiation runs to its end, and PW-01 that the current stays within the permitted limit, schedules included.
- The OCPP tab places the charger log beside the cable and compares the backend view with what happened on the cable. Batch mode with batch trends groups many depot sessions per charger and per car.
- The command line runner (
v2g-analyze) runs the same analysis on a folder of captures and writes JUnit or JSON, which fits a nightly depot test.
Sources
- OCPP 2.0.1: ChargingProfilePurposeEnumType, ChargingStationExternalConstraints, ChargingStationMaxProfile, TxDefaultProfile, TxProfile
- Solidstudio developer docs: Smart charging, stack levels, and the station applying the lowest of the profiles in force
- ISO 15118-2:2014 and ISO 15118-20:2022 message schemas as the analyzer decodes them (libcbv2g), AC_EVChargeParameter, SAScheduleTuple, PMaxSchedule, EVSENotification, PaymentOption; ISO 15118-20 DisplayParameters
- ChargePoint: answering questions about VDV 261, preconditioning through ISO 15118 value added services
- Tridens Technology: European bus depot case study (VDV), VDV 463 schedule based charging, VDV 261 preconditioning, priority groups by departure time
- SAE J3105:2023, Electric Vehicle Power Transfer System Using Conductive Automated Connection Devices; first issued January 2020, revised May 2023; parts /1, /2, /3
- ABB: Opportunity charging (HVC) product leaflet, 150, 300, 450 and 600 kW; IEC 61851-23 with DIN SPEC 70121 and ISO 15118; WLAN pairing
- Volvo Buses: Opportunity Charging System fact sheet, 2017
- NREL: Foothill Transit Battery Electric Bus Evaluation, final report, NREL/TP, 2021
- FTA Report No. 0254: Guidebook for Deploying Battery Electric Buses, August 2023
- FTA Report No. 0253: Procuring and Maintaining Battery Electric Buses and Charging Systems, August 2023
- Autocharge whitepaper, EVCCID (MAC address) from DIN SPEC 70121 as identifier, sent with OCPP Authorize