Test equipment for charging

What a charging lab uses: EV and charger emulators, conformance test systems, passive powerline tracers, CAN interfaces for CHAdeMO and GB/T, Control Pilot adapters and oscilloscopes, battery emulators and grid simulators, with the products as their makers describe them.

Emulate one side, or listen to both

Every charging test needs a partner for the device under test. Test equipment plays that partner, or it sits between two real devices and records what they say. Four kinds cover most benches:

KindPlays or measuresUsed for
EV emulatorThe car: Control Pilot states, the car modem, the car side of DIN 70121 or ISO 15118, and on DC a load or battery emulator behind itTesting a charger without a car, from conformance cases to end of line checks
EVSE emulatorThe charger: the Control Pilot PWM, the charger modem and the charger side of the protocol, with or without a power stageTesting a car or an onboard communication controller without a real charger
Passive tracer or snifferNothing; it listens to the powerline traffic and the Control Pilot between a real car and a real chargerField debugging, interoperability events and recording captures for analysis
Power equipmentBattery emulators, regenerative loads and grid simulatorsSupplying or absorbing the energy the emulated side would handle

Many commercial systems combine these: the same box can be set up as EV or as EVSE, and some can also trace a real pair.

Charging test systems

The table lists systems whose maker publishes what they do. Figures are as the maker or its press release states them; the date is when the source was published where it says so.

ProductMakerEmulates or measuresPower rangeProtocols
DS5366 Smart Charging Interface, now DS5366_ADVANCEDdSPACECharging communication module for a hardware in the loop simulator such as SCALEXIO; tests EV or charging station controllersCommunication and signal level; power comes from the rest of the HIL setupISO 15118 (DIN SPEC 70121, ISO 15118-2, ISO 15118-20 with the ADVANCED module), CHAdeMO, GB/T 27930 and GB/T 18487; TLS 1.2, TLS 1.3 or no TLS
SL1040A Scienlab Charging Discovery System, Portable SeriesKeysightEV and EVSE conformance, interoperability and end of line tests with time synchronous measurementUp to 400 A and 1000 V DC, up to 400 kWCCS (Type 1, Type 2, NACS: IEC 61851, SAE J1772, DIN SPEC 70121, ISO 15118), CHAdeMO 0.9, 1.x and 2.0, GB/T 18487 and GB/T 27930 (2011 and 2015)
SL1047A-HP4 Scienlab Charging Discovery System, High-Power SeriesKeysightEV and EVSE conformance, interoperability and functional tests at high powerData sheet: up to 1500 V DC, plus or minus 600 A, up to 1200 kW. January 2026 press release: scalable in software from 400 A and 1000 V to 800 A and 1500 VCCS (Type 1, Type 2, NACS), GB/T, CHAdeMO
SL1556A CCS Charging Protocol TracerKeysightPassive sniffer: Green PHY traffic and Control Pilot signal, bridged to Ethernet; viewed with the SL1487A trace viewerNone (listens only)DIN SPEC 70121, ISO 15118-3, IEC 61851-1 Ed. 3
EV Charging Analyzer (EVCA)comemsoEV or EVSE; two specimens in parallel or one combinedUp to 320 kW combined, sold in a 350 kW classIEC 61851-1, IEC 61851-23, DIN 70121, ISO 15118-2 and -3; CHAdeMO; GB/T 27930 (2011 and 2015)
Easy Chester Ultimate and Easy Chester Gen. 2comemsoMobile EV emulator for testing chargers in the field: function, communication and electrical safety (Ultimate)Gen. 2 Pro: DC load simulation up to 60 kW, 800 V systemsAC, DC CCS and CHAdeMO; DIN 70121, ISO 15118-2 and -3
VT5201 (VT System) and VH5110A CCS ListenerVectorVT5201: ISO 15118 test module for EV and EVSE. VH5110A: listens to the Control Pilot powerline traffic through an inductive coupler and hands it to CANoe as EthernetCommunication and signal levelIEC 61851, DIN 70121, ISO 15118, NACS
8000 EV and EVSE ATS with the 80713 simulatorChromaAC and DC EVSE testing, EV charging compatibility, liquid cooled high current tests; bidirectional supply for V2L, V2H and V2GNot stated in the source readCCS, NACS, CHAdeMO, GB/T, ChaoJi; ISO 15118-2 and ISO 15118-20
ComboCS (EVSE and EV versions)TrialogSimulates the EVSE or the EV of a CCS link without power transfer; nominal and non nominal test casesNone; the simulated charge limits are 32 A, 400 V, 22 kWIEC 61851-1, DIN 70121, ISO 15118-2 (AC and DC), EIM and Plug and Charge
9300 Battery Test SystemNH ResearchBattery emulator, regenerative DC load or bidirectional source for testing chargers and onboard chargers100 kW per system (600 V and 333 A, or 1200 V and 167 A), up to 1.2 MW in 100 kW stepsPower only
9410 Regenerative Grid SimulatorNH ResearchAC or DC source with three programmable channels, for Level 1 and 2 chargers and V2G12 kWPower only
BelayBoxPionixA complete AC charger for developers of the EVerest open source stack (Yeti power board, Yak high level board)11 kW or 22 kW ACIEC 61851-1, SAE J1772, ISO 15118-2

dSPACE has announced the end of life of the original DS5366. Its page says features for ISO 15118-20 from Release 2025-A come only with DS5366_ADVANCED, and that DS5366 users get updates until Release 2027-A.

Intrepid Control Systems, Elektrobit and Kempower were named as possible entries. The research for this page found no maker page describing a charging test product from them, so they are not listed. Check their current catalogues.

Conformance test systems

CharIN validates test systems for its conformance test programme (CharIN Conformance Test System, CCTS). A vendor goes through a validation of the system and its test cases per application profile; a validated system can then be used for CharIN conformance testing and for ordinary development testing.

  • CCS Basic covers the basic functions, AC charging and DC charging including high power charging.
  • CCS Extended adds smart charging, local and online load balancing, automatic paying, Plug and Charge (ISO 15118) and smart paying.
  • Keysight states that the SL1040A-ST2 and the SL1047A-HP4 are validated CCTS; the latter for both the Basic and the Extended profiles.
  • CharIN validated the comemso EVCA as a CCTS for DC EVSE, Basic and Extended, covering IEC 61851-1, IEC 61851-23, DIN 70121, ISO 15118-2 and ISO 15118-3.

How a test case is written and judged is in Anatomy of a test case; the conformance parts of ISO 15118 are in Conformance testing: ISO 15118-4, -5 and Testivals.

Powerline sniffers and how to capture

A sniffer is a HomePlug Green PHY modem coupled to the Control Pilot, with its traffic bridged to Ethernet where Wireshark or tcpdump records it. It can couple directly to CP and PE or through a clamp around the cable: Keysight sells both variants of its tracer, and the Vector VH5110A uses an inductive coupler for quick use in the field.

  • Qualcomm describes the QCA7005 as a Green PHY modem for EV charging that supports CCS. The Pionix Yak board, for one, carries it.
  • devolo sells its dLAN Green PHY eval board II configured for the vehicle side or the charger side under ISO/IEC 15118, DIN 70121 and SAE J2847/2, with PLC to Ethernet bridging, and publishes an SDK on GitHub.
  • The open source pyPLC project uses modified low cost powerline adapters. Its ListenMode sniffs the traffic between a CCS charger and a car; EvseMode and PevMode play either side. It needs Wireshark to view the traffic.
  • To see the IP traffic, the sniffer has to join the logical network of the pair, which setups do by reading the network key from the SLAC match. See HomePlug Green PHY: powerline on the Control Pilot and Stage: SLAC matching.

What to record, the settings that make a capture usable and the formats this analyzer reads are in Recording a charging session for analysis.

CAN for CHAdeMO and GB/T

CHAdeMO and GB/T 27930 talk over CAN on the charging cable, so their test systems carry CAN interfaces next to the power pins. Keysight lists CAN high and low, the GB/T signals CC1, CC2, A+ and A-, and the CHAdeMO signals on the SL1040A; comemso describes its CHAdeMO analyzer as measuring between car and charger, communication and load circuit, over the whole session; dSPACE names a CAN FD interface in its charging solution.

For recording alone any CAN interface that logs with timestamps works. The analyzer reads candump logs, Vector ASCII and PCAN traces, and CAN frames in a pcap recorded on a SocketCAN interface (Recording a charging session for analysis, CHAdeMO: DC charging over CAN, GB/T 27930: the Chinese DC protocol).

Control Pilot, load and grid

  • Charger test adapters put the connector pins on terminals. Kyoritsu (KEWEVSE), Sonel (EVSE-01) and others make adapters with CP and PE outputs for an oscilloscope, a rotary switch for the Control Pilot state (A, B, C, D) and one for the proximity resistor (open, 13, 20, 32 and 63 A).
  • An oscilloscope or data logger between CP and PE shows the states, the duty cycle and the 1 kHz PWM. For this analyzer sample at 20 kHz or more, so that each period has at least 20 points (Recording a charging session for analysis).
  • A battery emulator stands in for the traction battery when a DC charger is tested without a car. NH Research describes its 9300 as able to act as a fast source, a regenerative DC load or a bidirectional voltage source.
  • A grid simulator stands in for the mains: it lets a lab repeat undervoltage, frequency or phase conditions and absorb the energy a bidirectional charger exports.

Connect measurement equipment to a charging circuit only if you are qualified to and the equipment is rated for it. The Control Pilot is a low voltage signal next to mains or DC high voltage.

In this tool

  • Captures from a tracer, a sniffer or a test system load as pcap or pcapng; the analyzer finds the sessions, stages and findings in them.
  • A Control Pilot CSV from an oscilloscope or logger feeds the CP checks (CP-01 to CP-10) and the Alignment tab.
  • The Capture tool tells a message lost by the recorder from one the device never sent, which matters more with a sniffer than with a test system that takes part in the session.

Sources