Safety and type approval of chargers and cars

Which product safety and EMC standards a charger or a car is type tested against in each region, what the lab does on the bench (temperature rise, dielectric strength, residual current and insulation monitoring, EMC) and the marks and radio rules that follow.

Type test, certificate, mark

Safety approval follows the same pattern everywhere. A lab type tests samples of a design against a product standard. A certification body, or the maker itself where the law allows a declaration, confirms conformity. The product then carries the mark of the market, and in many schemes the certifier keeps inspecting the factory. Korea, for example, asks for factory inspections and product sampling tests every year under KC.

Safety approval is separate from communication conformance (Conformance testing: ISO 15118-4, -5 and Testivals), interoperability (Interoperability test events) and billing metrology (Billing and measurement testing). A charger can be safe and still fail to talk to a car.

The IEC family

StandardCoversNotes
IEC 61851-1:2017General requirements for EV supply equipmentSupply up to 1000 V AC or 1500 V DC; see IEC 61851-1: the Control Pilot
IEC 61851-21-1:2017EMC of the onboard charger while the vehicle is connected to the mainsTested on the whole vehicle or on the charger as an electronic sub assembly; not for trolley buses, rail and off road machines
IEC 61851-21-2:2018EMC of off board charging equipmentModes 1 to 4; input and output up to 1000 V AC or 1500 V DC. This edition holds only EMC tests and defines ports, set ups, limits and operating modes more precisely
IEC 61851-23DC charging stationsSee IEC 61851-23: DC charging stations
IEC 62196 seriesPlugs, socket outlets, vehicle connectors and inletsSee IEC 62196: plugs, sockets, connectors and inlets
IEC 62752 (edition 2, 2024)In cable control and protection device (IC-CPD) for mode 2A portable device that detects residual current, compares it with its operating value and opens the circuit
IEC 62955:2018Residual direct current detecting device (RDC-DD) for mode 3Detects 6 mA DC residual current; has no switching contacts of its own
IEC 61557-8Insulation monitoring devicesThe equipment standard for the IMD of a DC charger

Europe adopts these as EN standards; India adapts them into IS 17017; Korea publishes KC 61851-1:2022-11 aligned with IEC 61851-1; Australia and New Zealand refer to them directly.

North America

StandardCovers
UL 2594AC EV supply equipment, Level 1 and Level 2, for home, commercial and public use (Intertek: up to 1000 V AC, 50 or 60 Hz)
CSA C22.2 No. 280The Canadian twin of UL 2594, tri national with NMX-J-677-ANCE for Mexico. The 2013 and 2016 editions covered equipment on a supply of 600 V AC or less at 60 Hz; the third edition of 2022 raised the scope to 1000 V AC or less at 50 or 60 Hz, the figure Intertek quotes for UL 2594
UL 2202DC charging equipment, input up to 1000 V AC or 1500 V DC
UL 2231-1 and UL 2231-2Personnel protection systems for EV supply circuits: general requirements and the protective devices
UL 9741EV power export equipment: off board unidirectional and bidirectional equipment up to 1000 V AC and 1500 V DC with a permanently attached connector, including grid parallel operation. Harmonized with CSA C22.2 No. 348

These products are installed under the National Electrical Code (NFPA 70) in the US and the Canadian Electrical Code, Part I. Third party labs test to them; Intertek, for example, offers testing to UL 2594 and UL 2202.

Asia and Oceania

MarketStandardsApproval
ChinaGB/T 18487.1-2023, general requirements of the conductive charging system: issued 7 September 2023, in force 1 April 2024CCAP revised its EV supply equipment certification rules (CCAP-GZ-464230:2024) on 27 March 2024; certificates to the old edition had to move to the new one by 1 April 2025. Since 1 August 2026 AC and DC EV supply equipment needs the compulsory CCC certificate (SAMR announcement 2024 No. 50, implementation rules CNCA-C25-01:2024), see China: GB/T charging, CCC certification and the largest charging network
JapanJIS D 61851-23 (DC charging stations, 2014 edition) and the JIS versions of IEC 61851 and IEC 62196PSE mark under the Electrical Appliance and Material Safety Law (DENAN); radios fall under the Radio Law
KoreaKC 61851-1:2022-11, aligned with IEC 61851-1; KEC 241.17 for installationsKC mark under the Electrical Appliance Safety Management Act, run by KATS since 1 January 2009
IndiaIS 17017 in three parts: part 1 general requirements, part 2 connectors adapted from IEC 62196-1 to -3, and parts adapted from IEC 61851-21 (EMC), -23 (DC) and -24 (DC communication)BIS
Australia and New ZealandIEC 61851, IEC 62196, IEC 62752, the heat and fire clause 30.2 of AS/NZS 60335.1, and the wiring rules AS/NZS 3000 for installationRCM mark once full compliance is shown; charge cables with an in cable RCD are in scope Level 1 equipment under AS/NZS 4417

Which chargers are specified products under the Japanese PSE rules, and the exact IS 17017 part numbers, were not confirmed from primary sources for this page. See the region pages and check with the certifier.

On the bench

  • Temperature rise: the charger runs at rated current until temperatures settle, and terminals, contacts and touchable surfaces are compared with limits. Test labs such as Tecnalia list temperature rise and dielectric properties among their standard tests for charging systems.
  • Dielectric strength: an AC withstand voltage between live parts and the enclosure or protective earth, and an impulse test, check the insulation.
  • Ingress (IP code) and impact (IK code) protection of enclosures and connectors, for the location the charger is rated for.
  • Residual current protection: under IEC 60364-7-722, where the charger does not itself disconnect on a DC fault current above 6 mA, the installation needs a type B RCD, or a type A or F RCD together with an RDC-DD. The RDC-DD often sits inside the charger with the RCD upstream.
  • Insulation monitoring in DC chargers: the IMD must detect a falling insulation resistance on an unearthed DC output. Design notes for IEC 61851-23 chargers use 100 ohm per volt as the fault limit and 500 ohm per volt as the healthy limit; see Isolation monitoring and CableCheck.
  • EMC: emission and immunity of the charger under IEC 61851-21-2, and of the car in "REESS charging mode coupled to the power grid" under UNECE Regulation No. 10, which asks for radiated and conducted emissions and immunity and a test plan agreed between the technical service and the maker.

Specific limits (temperature rise per material, test voltages and durations, the IP and IK codes a standard asks for outdoor chargers) were seen only in secondary summaries during research and are left out. Take them from the clause of the standard.

Marks, radios and the EU

  • EU: the CE mark on a charger rests on the Low Voltage Directive 2014/35/EU (50 to 1000 V AC, 75 to 1500 V DC), the EMC Directive 2014/30/EU and, for a charger with WiFi, Bluetooth or cellular, the Radio Equipment Directive 2014/53/EU.
  • Since 2025 a charger with a radio also meets the cybersecurity requirements of RED Article 3(3), with the EN 18031 series as the harmonised route (BSI guidance); see Security testing of chargers.
  • UK: BSI names the Electric Vehicles (Smart Charge Points) Regulations and the PSTI regulations as adding cybersecurity requirements for chargers sold there.
  • Great Britain: the government announced on 1 August 2023 that the CE mark stays recognised beyond the end of 2024, next to UKCA. The Product Safety and Metrology etc. (Amendment) Regulations 2024, in force from 1 October 2024, removed the end date for 21 product regulations, among them the rules for radio equipment.
  • US: FCC rules in 47 CFR Part 15 cover unintentional radiators, usually by supplier declaration; a charger with a radio module is an intentional radiator that needs certification and an FCC ID. Wireless power transfer is handled under Part 15 or Part 18 depending on how it works.

In this tool

The analyzer does not test safety. It sees two things a safety design drives: the Control Pilot states, for example CP-09 on state F during energy transfer (with a CP log), and in DC sessions the cable check, where the charger tests the insulation before energy flows (Stage: DC cable check and isolation test). The demo cablecheck-fail shows a charger that answers the cable check with FAILED. A failed cable check in a capture is a lead for the IMD, not a safety verdict.

Sources