Kinds of chargers
From a portable cable on a household socket to a megawatt truck charger: the IEC 61851 charging modes, the North American levels, AC and DC wallboxes, split systems, battery buffered chargers, pantographs, MCS, wireless charging and battery swapping, and what each one looks like in a capture.
Modes and levels
IEC 61851-1 sorts conductive charging into four modes by how the car is connected and what protects it. The mode says nothing about the power: a Mode 3 wallbox and a Mode 4 truck charger can differ by a factor of a hundred.
| Mode | Connection | Control and protection | Limits |
|---|---|---|---|
| Mode 1 | Ordinary household or industrial socket | None in the cable; no Control Pilot | At most 16 A, 250 V single phase or 480 V three phase; many countries forbid or restrict it |
| Mode 2 | Ordinary socket, through a cable with an IC-CPD | The IC-CPD (IEC 62752) generates the Control Pilot and adds residual current protection | At most 32 A, 250 V single phase or 480 V three phase |
| Mode 3 | Dedicated AC supply equipment: a wallbox or a public AC charge point | Control Pilot and protection in the fixed equipment | Set by the installation and the cable (see Measured current, permitted current and the cable) |
| Mode 4 | Off-board DC charger | The charger converts the power and controls it; CCS, CHAdeMO and GB/T DC are Mode 4 | Set by the charger, see IEC 61851-23: DC charging stations |
North America uses the levels of SAE J1772 instead: AC Level 1 on 120 V, AC Level 2 on 208 to 240 V up to 80 A, and two DC levels for off-board chargers. SAE J1772: the North American coupler and pilot has the table.
"Level 3" is not one of those levels. It is the everyday name for DC fast charging in North America; in J1772 terms such a charger is DC Level 1 or DC Level 2. InsideEVs argued that the term is wrong; CleanTechnica argued in January 2023 that it is common enough to be legitimate. The analyzer does not use the term.
Early J1772 drafts are reported to have defined an AC Level 3 that was never used. Check this against the revision history of SAE J1772 before relying on it.
AC: wallboxes and portable cables
An AC charger does not convert energy; the onboard charger in the car does (see Inside a charger and The car side of charging). Its power is therefore the supply voltage times the current the pilot allows times the number of phases, and the car may take less.
- Single phase at 230 V: about 3.7 kW at 16 A and 7.4 kW at 32 A.
- Three phase at 400 V: about 11 kW at 16 A and 22 kW at 32 A. A car with a single phase onboard charger draws only on L1.
- North America, split phase 240 V: up to 80 A under J1772, about 19 kW.
- Mode 2 portable cable: the IC-CPD in the cable does what the wallbox does, on a smaller scale. In North America, Level 1 cord sets on 120 V work the same way.
Several wallboxes on one supply share it by lowering the duty cycle each one offers. The open source SmartEVSE controller, for example, shares one mains connection between up to eight units and raises or lowers the current it offers to each car. In a Control Pilot log that is a change of duty cycle in the middle of charging; PW-01 follows the permitted current as it changes.
DC: from wallbox to split system
- DC wallbox: a small off-board charger on a wall or pedestal. ABB lists its Terra DC wallbox at up to 24 kW and its Terra 24 to Terra 54 at 20 to 50 kW; sites are depots, dealers and workplaces where the grid connection is limited.
- All in one fast charger: the power modules, the controller and the cable sit in one cabinet. The ABB brochure lists Terra 94, 124 and 184 at 90, 120 and 180 kW.
- Split system: a power cabinet with the rectifiers and DC/DC modules feeds one or more dispensers that hold the cable, the display and the communication controller. The cabinet shifts its modules between dispensers, so the power one car gets depends on what the others draw.
- Battery buffered charger: a battery inside the charger is filled from a small grid connection or local solar and emptied into the car at high power. ADS-TEC Energy describes its ChargeBox (a separate battery booster with two dispensers) at up to 320 kW and its ChargePost (buffer and two charging points in one unit) at up to 300 kW.
To the car all of these look the same: an off-board DC charger with its limits. Power sharing and an emptying buffer show only as the limits the charger announces, for example a lower EVSEMaximumPowerLimit or EVSEPowerLimitAchieved set in the charge loop. The capture shows that the charger limited the power, not why.
Mobile chargers (a battery on a van, a trailer or a wheeled unit that charges a car where it stands) are sold as products, but their power ranges and interfaces were not confirmed for this page.
Buses and trucks: pantographs and MCS
SAE published J3105 in January 2020 for automated conductive connection devices, with three parts: J3105/1 for a pantograph on the infrastructure that comes down onto rails on the bus roof, J3105/2 for a pantograph on the vehicle that goes up to the infrastructure, and J3105/3 for an enclosed pin and socket connection. The IEC counterpart is IEC 61851-23-1:2026 for DC supply equipment with an automated connection device (ACD), up to 1 500 V DC on the vehicle side.
A pantograph has no plug to carry the pilot before contact, so bus and charger pair over WLAN as the bus approaches, and the charging communication follows ISO 15118. ISO 15118-20 has an ACDP service for this, with its own messages.
The published summaries of J3105 give two current levels, up to 600 A and up to 1 200 A, between 250 and 1 000 V, and name IEEE 802.11 for the pairing. Check the current levels, the WLAN variant and whether the session moves to the Control Pilot after contact against the SAE and IEC texts.
The Megawatt Charging System (MCS) is the plug for heavy trucks. SAE published J3271 as a technical information report in March 2025, and the IEC published IEC TS 63379 for the connector, inlet and cable in February 2026. The design target is up to 3 000 A and 1 250 V. The communication is ISO 15118-20 over 10BASE-T1S Ethernet, so there is no SLAC. MCS: the Megawatt Charging System covers it in detail.
Wireless charging and battery swapping
SAE J2954 sets the interoperability, safety and test requirements for wireless charging of light duty vehicles; its current revision is from August 2024. It defines three classes: WPT1 up to 3.7 kW, WPT2 up to 7.7 kW and WPT3 up to 11 kW. In the IEC, the IEC 61980 series covers the same ground, and IEC 61980-3 is written to work with ISO 15118-20.
Wireless charging needs communication before any power flows, to find and align the pad. ISO 15118-20 has a WPT service with its own messages, and ISO 15118-8 describes the wireless link that carries them (see ISO 15118-8: wireless communication).
Battery swapping replaces the pack instead of charging it in the car. IEC TS 62840-1 (2016) gives the general guidance for swap systems and IEC 62840-2 the safety requirements, published in Europe as EN IEC 62840-2:2025. electrive reported in January 2025 that DIN was working with NIO on a German standard based on this series. NIO reported that the first stations of its fourth generation Power Swap Station went live in June 2024, able to swap packs of several brands and models.
A swap station charges its packs inside the station. There is no car to charger session to capture at the station, and nothing in it for this analyzer.
Side by side
| Type | Typical power | Supply | Where used | Communication | In a capture for this analyzer |
|---|---|---|---|---|---|
| Mode 2 portable cable | Up to 32 A (Mode 2 limit); Level 1 cord sets on 120 V | Household or industrial socket | Home, travel, emergency | Control Pilot PWM from the IC-CPD | A CP log with a nominal duty cycle; no SLAC or V2G messages |
| AC wallbox (Mode 3) | 3.7 to 22 kW in Europe, up to about 19 kW in North America | Mains, single or three phase | Home, workplace, street | PWM; optional ISO 15118-2 or -20 AC over PLC; OCPP to the backend | CP log; with digital communication a 5 percent duty cycle, SLAC, SDP and the AC messages (An AC session, message by message) |
| DC wallbox | About 20 to 50 kW | Three phase AC | Depots, dealers, workplaces | CCS (DIN SPEC 70121, ISO 15118); CHAdeMO or GB/T over CAN where fitted | A DC session: CableCheck, PreCharge, the charge loop (A DC session, message by message), or CAN frames |
| All in one DC fast charger | Tens to a few hundred kW (ABB lists 90 to 180 kW) | Three phase AC | Highway, retail, urban hubs | As the DC wallbox; OCPP to the backend | As the DC wallbox; the power limits reflect the modules |
| Split system (cabinet and dispensers) | Shared between dispensers | Three phase AC to the cabinet | Highway, depots, bus and truck sites | The communication controller sits in the dispenser | As the DC wallbox; power sharing shows only as changing limits |
| Battery buffered charger | Up to about 300 kW from a small grid connection | Low power AC plus an internal battery | Sites with a weak grid | As the DC wallbox | As the DC wallbox |
| Pantograph (ACD) | Several hundred kW (see the verify note above) | Grid | Bus depots and route ends | WLAN pairing, ISO 15118; ISO 15118-20 ACDP | V2G messages without HomePlug frames; the ACDP messages of ISO 15118-20 are decoded |
| MCS | Up to 3 000 A and 1 250 V by design | Grid | Truck depots and corridors | ISO 15118-20 over 10BASE-T1S | V2G messages without SLAC; the MCS specific parts are not decoded |
| Wireless (WPT) | 3.7, 7.7 or 11 kW (J2954 WPT1 to WPT3) | Mains to the ground pad | Home and fleet parking | ISO 15118-20 WPT over a wireless link | The WPT messages of ISO 15118-20 are decoded when the IP traffic is captured |
| Battery swap station | Not applicable | Grid | Stations run by a car maker, for example NIO | Inside the station | Nothing to capture |
In this tool
- A Control Pilot log from any Mode 2 or Mode 3 charger is read with the CP, PW and PP checks. The limit profile for IEC 61851-1 or for SAE J1772 and J3400 is suggested from the EVSEID country or a North American supply voltage (Limit profiles: the numbers behind every check).
- A network capture from an AC or DC charger with digital communication is read from SLAC to SessionStop. The demos ac-ok and iso20 show both.
- CHAdeMO and GB/T sessions are read from their CAN frames, from a pcap or a CAN text log; see the chademo and gbt demos.
- On a link without HomePlug, such as MCS, a pantograph or wireless, SLAC shows as not in the capture instead of failed, and the session facts name the link (FR-STD-02).
- The ACDP and WPT messages of ISO 15118-20 are decoded with the same codec as the AC and DC messages.
- What happens inside a split system or a battery buffer, and the backend, is not on the charging cable. An OCPP log of the charger can be loaded beside the capture (OCPP 2.0.1 and ISO 15118: the backend behind the cable).
Sources
- IEC 61851-1:2017, the four charging modes and the Control Pilot
- IEC 62752, in-cable control and protection device (IC-CPD) for Mode 2
- All About Circuits: The four EV charging modes in the IEC 61851 standard, current and voltage limits of Mode 1 and Mode 2
- Monta: IEC 61851, definition, scope and role in EV charging, Mode 3 and Mode 4
- SAE J1772, AC Level 1 and 2, DC Level 1 and 2
- InsideEVs: There is no such thing as a Level 3 EV charger
- CleanTechnica: Level 3 is a perfectly legitimate term for DC fast charging, 16 January 2023, the other side of the argument
- ABB E-mobility: Terra DC wallbox, product page
- ABB E-mobility product brochure, the DC range from the DC wallbox to Terra HP
- ADS-TEC Energy press release: battery buffered ultra fast charging with ChargePost, 2022
- SmartEVSE v3, open source AC charging controller with power sharing
- Green Car Congress: SAE publishes standard for on-route mechanized charging, SAE J3105 and J3105/1 to /3, January 2020
- SAE J3105/1_202001, infrastructure mounted pantograph (cross rail) connection
- IEC 61851-23-1:2026, DC supply equipment with an automated connection device
- Vector: Charging by pantograph, technical article, WLAN pairing of bus and charger
- SAE: J3271 Megawatt Charging System technical information report published, March 2025
- CharIN: official publication of IEC TS 63379, February 2026
- SAE J2954_202408, wireless power transfer for light duty vehicles, WPT1 to WPT3
- ISO 15118-20:2022 and ISO 15118-8, WPT and ACDP services; the wireless communication link
- IEC 61980-3, wireless power transfer, magnetic field systems
- IEC TS 62840-1:2016, battery swap systems, general and guidance
- EN IEC 62840-2:2025, battery swap systems, safety requirements
- electrive: German DIN working with NIO on battery swapping standards, 28 January 2025
- NIO: Power Swap Station 4.0 now operational, June 2024
- SPEC.md of this tool, section 4 (input formats), FR-STD-01 and FR-STD-02