Charging around the world

One page for the whole world: the AC and DC connectors, the high level communication, the backend protocol, the mains supply and the main public charging rule of each major market, then the three families of DC communication, the adapters between them and megawatt charging for trucks.

How to read this map

Each row names what a charger in that market most likely has at the end of its cables and what it speaks. The DC connector decides the family of communication: CCS1, CCS2 and J3400 use powerline on the Control Pilot, CHAdeMO and GB/T use CAN. The region articles carry the detail and the sources.

Cells marked (verify) and the whole mains column were not confirmed against a primary source in this review; they follow general references and will be checked. "Not confirmed" means no source was found yet.

Country and region table

MarketAC connectorDC connector(s)High level communicationBackendMains (verify)Main public charging rule or programRead more
European UnionType 2CCS2; CHAdeMO on older carsPLC: DIN SPEC 70121: DC charging, the early CCS protocol, ISO 15118-2: the first generation application layer, ISO 15118-20: the second generationOCPP: the charger's link to its backend common (verify)230/400 V, 50 HzAFIR, Regulation (EU) 2023/1804, applies from 13 April 2024Europe: AFIR, Type 2, CCS2 and ISO 15118
United KingdomType 2CCS2 (Combo 2)PLCOCPI open data under the 2023 regulations; OCPP: the charger's link to its backend common but not a legal duty230/400 V, 50 HzSmart Charge Points Regulations 2021; Public Charge Point Regulations 2023United Kingdom: smart charge points, the Public Charge Point Regulations and Type 2 with CCS2
NorwayType 2 (verify)CCS2; CHAdeMO on older cars (verify)PLCNot confirmed230 V, 50 Hz; many IT networksNot confirmedEurope: AFIR, Type 2, CCS2 and ISO 15118
United StatesType 1 (SAE J1772: the North American coupler and pilot); SAE J3400: the NACS couplerCCS1, J3400; CHAdeMO on older carsPLCOCPP 2.0.1 and OCPI 2.2.1 for NEVI sites120/240 V split phase, 208 V in three phase buildings, 60 HzNEVI standards, 23 CFR Part 680, published 28 February 2023North America: J1772, CCS1, J3400 and the NEVI standards
CanadaType 1; J3400CCS1, J3400PLCNot confirmed120/240 V, 60 HzMeasurement Canada dispensations (from 2022); ZEVIP fundingNorth America: J1772, CCS1, J3400 and the NEVI standards
MexicoType 1CCS1; GB/T and Tesla seenPLCNot confirmed127/220 V, 60 HzNOM-001-SEDE-2012 Article 625North America: J1772, CCS1, J3400 and the NEVI standards
BrazilType 2CCS2; some GB/T, older CHAdeMOPLCNot confirmed127 V or 220 V by region, 60 HzANEEL REN 1.000/2021, which replaced REN 819 of 2018Latin America: Type 2 and CCS2 in Brazil, Chile, Colombia, Argentina, Uruguay and Costa Rica
ChileType 2; GB/T allowedCCS2; GB/T (verify)PLC for CCS2Not confirmed220 V, 50 HzLaw 21.305; Decree 12 (2022); RIC N°15 (2024)Latin America: Type 2 and CCS2 in Brazil, Chile, Colombia, Argentina, Uruguay and Costa Rica
ColombiaType 2CCS2PLCOCPI 2.2.1 (verify)120 V, 60 HzResolution 40223 (2021); Resolution 40123 (April 2024)Latin America: Type 2 and CCS2 in Brazil, Chile, Colombia, Argentina, Uruguay and Costa Rica
ChinaGB/T 20234.2GB/T 20234.3; ChaoJi and CHAdeMO 3.0 as the next generationCAN: GB/T 27930: the Chinese DC protocolNot confirmed220/380 V, 50 HzGB/T 18487.1, GB/T 20234 and GB/T 27930, 2015 editions, in force from 2016China: GB/T charging, CCC certification and the largest charging network
JapanType 1CHAdeMO: DC charging over CANCAN: CHAdeMONot confirmed100/200 V; 50 Hz in the east, 60 Hz in the westNot confirmedJapan: CHAdeMO, Type 1 and the 300,000 port target
South KoreaType 1CCS1 (Combo 1); older CHAdeMOPLCOCPP 1.6 certification in the ministry charger program (2025)220/380 V, 60 HzCombo 1 as the single DC method (KS revision, 2017); smart control chargers from 2025South Korea: Combo 1, KC certification and smart control chargers
IndiaType 2; Bharat AC-001CCS2; Bharat DC-001 (GB/T connector, 15 kW)PLC; CAN for DC-001OCPP and OCPI in the Ministry of Power guidelines (2024)230/400 V, 50 HzMinistry of Power guidelines, 17 September 2024; PM E-DRIVE to 31 March 2028India: from Bharat chargers to CCS2, IS 17017 and PM E-DRIVE
SingaporeType 2CCS2 in publicPLCEVCO licence with data sharing230/400 V, 50 HzElectric Vehicles Charging Act, from 8 December 2023; type approval from 8 June 2024Southeast Asia: Type 2 and CCS2 from Singapore to the Philippines
ThailandType 2CCS2; some CHAdeMOPLC; CAN for CHAdeMONot confirmed230/400 V, 50 HzMandatory TIS standards approved 21 July 2026Southeast Asia: Type 2 and CCS2 from Singapore to the Philippines
IndonesiaType 2CCS2, CHAdeMOPLC; CAN for CHAdeMONot confirmed230/400 V, 50 HzESDM Regulation 1/2023Southeast Asia: Type 2 and CCS2 from Singapore to the Philippines
MalaysiaType 2CCS2; CHAdeMO permittedPLC; CAN for CHAdeMONot confirmed230/400 V, 50 HzLow Carbon Mobility Blueprint 2021 to 2030; charger approval rules of 21 June 2024Southeast Asia: Type 2 and CCS2 from Singapore to the Philippines
VietnamType 2CCS2PLCNot confirmed220/380 V, 50 HzNational technical regulation (QCVN) due by 30 September 2026Southeast Asia: Type 2 and CCS2 from Singapore to the Philippines
PhilippinesType 2CCS2PLCNot confirmed230 V, 60 HzEVIDA, Republic Act 11697 (15 April 2022)Southeast Asia: Type 2 and CCS2 from Singapore to the Philippines
AustraliaType 2CCS2; CHAdeMO at some older sitesPLCOCPP 2.0.1 encouraged for funded sites; South Australia requires OCPP 1.6 or an equivalent (2024)230/400 V, 50 HzNational Electric Vehicle Strategy (2023); minimum operating standards for funded sites (2024)Australia and New Zealand
New ZealandType 2; Type 1 on Japanese importsCCS2 and CHAdeMO side by sidePLC; CAN for CHAdeMONot confirmed230/400 V, 50 HzGoal of 10,000 public charge points by 2030; zero interest loans (2025, 2026)Australia and New Zealand
United Arab EmiratesType 2CCS2 (Dubai public equipment); CHAdeMO on older DEWA chargersPLCOCPP 1.6J at least (Dubai)230/400 V, 50 HzDubai EV Charging Infrastructure Regulation (2024); Cabinet Resolution 81 of 2024 on tariffsMiddle East and Africa
Saudi ArabiaType 2 (verify)CCS2 (verify)PLCNot confirmed230/400 V, 60 HzMOMRAH technical requirements (1442 H); EVIQ, more than 5,000 fast chargers by 2030Middle East and Africa
IsraelType 2CCS2PLCNot confirmed230/400 V, 50 HzNot confirmedMiddle East and Africa
TurkeyType 2 (verify)CCS2 (verify)PLCNot confirmed230/400 V, 50 HzCharging Service Regulation (2022), EPDK operator licences; amended 2026Middle East and Africa
South AfricaType 2 (verify)CCS2 (verify)PLCNot confirmed230/400 V, 50 HzNot confirmedMiddle East and Africa

Where a row says PLC, the charger and the car first agree on a protocol in the supportedAppProtocol handshake: DIN SPEC 70121: DC charging, the early CCS protocol, ISO 15118-2: the first generation application layer or ISO 15118-20: the second generation. See The app protocol handshake.

Three families of DC communication

FamilyPhysical linkProtocolsConnectorsWhere
Powerline (PLC)HomePlug Green PHY on the Control Pilot wire, paired by SLAC (ISO 15118-3: powerline communication and SLAC); IPv6, TCP, optionally TLSDIN SPEC 70121: DC charging, the early CCS protocol, ISO 15118-2: the first generation application layer, ISO 15118-20: the second generation, all EXI encodedCCS1, CCS2, J3400Europe, North America, Korea, India, Australia and most markets that follow them
CAN, CHAdeMOCAN at 500 kbit/s plus analogue start and enable linesCHAdeMO: DC charging over CANCHAdeMOJapan, and older cars worldwide
CAN, GB/TCAN at 250 kbit/s with SAE SAE J1939 on a charging bus addressing, plus CC1 and CC2 connection lines and a 12 V auxiliary supplyGB/T 27930: the Chinese DC protocolGB/T 20234.3China

The families differ below the application layer, so a capture of each looks different. PLC needs a sniffer on the pilot or a network tap behind the modem; a CAN session needs a CAN logger on the communication pair. ChaoJi and CHAdeMO 3.0 keeps CAN but moves to a new, smaller connector; the Megawatt Charging System keeps ISO 15118-20: the second generation but replaces powerline with an Ethernet pair. See How the charging standards fit together and Recording a charging session for analysis.

How adapters bridge them

  • Same family, different shape: CCS1 and J3400 share the Control Pilot signalling and the protocols. A CCS1 to J3400 adapter only routes contacts (pilot, proximity, power) and translates nothing. See SAE J3400: the NACS coupler.
  • Same family, CAN on both sides: the plan for ChaoJi and CHAdeMO 3.0 is that adapters let a ChaoJi car use existing CHAdeMO or GB/T chargers, because both sides speak closely related CAN protocols.
  • Different families: between PLC and CAN a passive adapter cannot work. An active adapter has its own controller and speaks one protocol to the car and the other to the charger. A capture on each side then shows a different conversation, and a fault may lie in the adapter itself.
  • Any adapter adds contact resistance and its own temperature limit; a car or charger may limit current when it knows an adapter is present. Reduced power through an adapter is not by itself a protocol fault.

When testing through an adapter, record its make and firmware in the report, and capture on the charger side as well as the car side if you can. See Interoperability test events.

Megawatt charging for trucks

The Megawatt Charging System (MCS: the Megawatt Charging System) is the heavy vehicle connector of the CCS world: IEC TS 63379 and SAE J3271 describe the coupler, and the car to charger link is ISO 15118-20: the second generation over 10BASE-T1S single pair Ethernet in place of powerline. Its session layer is therefore the same as on a CCS2 cable once the Ethernet link is up.

Where MCS chargers are being deployed (European and North American truck corridors) and whether China uses a megawatt standard of its own were not confirmed from a primary source in this review. See Heavy duty trucks and the Megawatt Charging System for the deployment picture.

In this tool

  • The tool reads all three families: the PLC protocols from pcap captures (with the IS20 checks for ISO 15118-20), CHAdeMO and GB/T 27930 from CAN frames (with the CAN, CH and GB checks). The demos below show one session of each.
  • The format of a file is decided by reading it, not by its name, so a capture from any market opens the same way.
  • Two limit profiles ship: the IEC 61851-1 and ISO 15118-2 defaults (230 V nominal) and SAE J1772 and J3400 for North America (240 V). A market with another supply, such as 100 V or 200 V in Japan, needs a copied profile with its own value. See Limit profiles: the numbers behind every check.
  • ChaoJi sessions are not decoded yet, and MCS captures are read on the Ethernet pair as ISO 15118-20. See ChaoJi and CHAdeMO 3.0 and MCS: the Megawatt Charging System.

Sources