Charging around the world
One page for the whole world: the AC and DC connectors, the high level communication, the backend protocol, the mains supply and the main public charging rule of each major market, then the three families of DC communication, the adapters between them and megawatt charging for trucks.
How to read this map
Each row names what a charger in that market most likely has at the end of its cables and what it speaks. The DC connector decides the family of communication: CCS1, CCS2 and J3400 use powerline on the Control Pilot, CHAdeMO and GB/T use CAN. The region articles carry the detail and the sources.
Cells marked (verify) and the whole mains column were not confirmed against a primary source in this review; they follow general references and will be checked. "Not confirmed" means no source was found yet.
Country and region table
| Market | AC connector | DC connector(s) | High level communication | Backend | Mains (verify) | Main public charging rule or program | Read more |
|---|---|---|---|---|---|---|---|
| European Union | Type 2 | CCS2; CHAdeMO on older cars | PLC: DIN SPEC 70121: DC charging, the early CCS protocol, ISO 15118-2: the first generation application layer, ISO 15118-20: the second generation | OCPP: the charger's link to its backend common (verify) | 230/400 V, 50 Hz | AFIR, Regulation (EU) 2023/1804, applies from 13 April 2024 | Europe: AFIR, Type 2, CCS2 and ISO 15118 |
| United Kingdom | Type 2 | CCS2 (Combo 2) | PLC | OCPI open data under the 2023 regulations; OCPP: the charger's link to its backend common but not a legal duty | 230/400 V, 50 Hz | Smart Charge Points Regulations 2021; Public Charge Point Regulations 2023 | United Kingdom: smart charge points, the Public Charge Point Regulations and Type 2 with CCS2 |
| Norway | Type 2 (verify) | CCS2; CHAdeMO on older cars (verify) | PLC | Not confirmed | 230 V, 50 Hz; many IT networks | Not confirmed | Europe: AFIR, Type 2, CCS2 and ISO 15118 |
| United States | Type 1 (SAE J1772: the North American coupler and pilot); SAE J3400: the NACS coupler | CCS1, J3400; CHAdeMO on older cars | PLC | OCPP 2.0.1 and OCPI 2.2.1 for NEVI sites | 120/240 V split phase, 208 V in three phase buildings, 60 Hz | NEVI standards, 23 CFR Part 680, published 28 February 2023 | North America: J1772, CCS1, J3400 and the NEVI standards |
| Canada | Type 1; J3400 | CCS1, J3400 | PLC | Not confirmed | 120/240 V, 60 Hz | Measurement Canada dispensations (from 2022); ZEVIP funding | North America: J1772, CCS1, J3400 and the NEVI standards |
| Mexico | Type 1 | CCS1; GB/T and Tesla seen | PLC | Not confirmed | 127/220 V, 60 Hz | NOM-001-SEDE-2012 Article 625 | North America: J1772, CCS1, J3400 and the NEVI standards |
| Brazil | Type 2 | CCS2; some GB/T, older CHAdeMO | PLC | Not confirmed | 127 V or 220 V by region, 60 Hz | ANEEL REN 1.000/2021, which replaced REN 819 of 2018 | Latin America: Type 2 and CCS2 in Brazil, Chile, Colombia, Argentina, Uruguay and Costa Rica |
| Chile | Type 2; GB/T allowed | CCS2; GB/T (verify) | PLC for CCS2 | Not confirmed | 220 V, 50 Hz | Law 21.305; Decree 12 (2022); RIC N°15 (2024) | Latin America: Type 2 and CCS2 in Brazil, Chile, Colombia, Argentina, Uruguay and Costa Rica |
| Colombia | Type 2 | CCS2 | PLC | OCPI 2.2.1 (verify) | 120 V, 60 Hz | Resolution 40223 (2021); Resolution 40123 (April 2024) | Latin America: Type 2 and CCS2 in Brazil, Chile, Colombia, Argentina, Uruguay and Costa Rica |
| China | GB/T 20234.2 | GB/T 20234.3; ChaoJi and CHAdeMO 3.0 as the next generation | CAN: GB/T 27930: the Chinese DC protocol | Not confirmed | 220/380 V, 50 Hz | GB/T 18487.1, GB/T 20234 and GB/T 27930, 2015 editions, in force from 2016 | China: GB/T charging, CCC certification and the largest charging network |
| Japan | Type 1 | CHAdeMO: DC charging over CAN | CAN: CHAdeMO | Not confirmed | 100/200 V; 50 Hz in the east, 60 Hz in the west | Not confirmed | Japan: CHAdeMO, Type 1 and the 300,000 port target |
| South Korea | Type 1 | CCS1 (Combo 1); older CHAdeMO | PLC | OCPP 1.6 certification in the ministry charger program (2025) | 220/380 V, 60 Hz | Combo 1 as the single DC method (KS revision, 2017); smart control chargers from 2025 | South Korea: Combo 1, KC certification and smart control chargers |
| India | Type 2; Bharat AC-001 | CCS2; Bharat DC-001 (GB/T connector, 15 kW) | PLC; CAN for DC-001 | OCPP and OCPI in the Ministry of Power guidelines (2024) | 230/400 V, 50 Hz | Ministry of Power guidelines, 17 September 2024; PM E-DRIVE to 31 March 2028 | India: from Bharat chargers to CCS2, IS 17017 and PM E-DRIVE |
| Singapore | Type 2 | CCS2 in public | PLC | EVCO licence with data sharing | 230/400 V, 50 Hz | Electric Vehicles Charging Act, from 8 December 2023; type approval from 8 June 2024 | Southeast Asia: Type 2 and CCS2 from Singapore to the Philippines |
| Thailand | Type 2 | CCS2; some CHAdeMO | PLC; CAN for CHAdeMO | Not confirmed | 230/400 V, 50 Hz | Mandatory TIS standards approved 21 July 2026 | Southeast Asia: Type 2 and CCS2 from Singapore to the Philippines |
| Indonesia | Type 2 | CCS2, CHAdeMO | PLC; CAN for CHAdeMO | Not confirmed | 230/400 V, 50 Hz | ESDM Regulation 1/2023 | Southeast Asia: Type 2 and CCS2 from Singapore to the Philippines |
| Malaysia | Type 2 | CCS2; CHAdeMO permitted | PLC; CAN for CHAdeMO | Not confirmed | 230/400 V, 50 Hz | Low Carbon Mobility Blueprint 2021 to 2030; charger approval rules of 21 June 2024 | Southeast Asia: Type 2 and CCS2 from Singapore to the Philippines |
| Vietnam | Type 2 | CCS2 | PLC | Not confirmed | 220/380 V, 50 Hz | National technical regulation (QCVN) due by 30 September 2026 | Southeast Asia: Type 2 and CCS2 from Singapore to the Philippines |
| Philippines | Type 2 | CCS2 | PLC | Not confirmed | 230 V, 60 Hz | EVIDA, Republic Act 11697 (15 April 2022) | Southeast Asia: Type 2 and CCS2 from Singapore to the Philippines |
| Australia | Type 2 | CCS2; CHAdeMO at some older sites | PLC | OCPP 2.0.1 encouraged for funded sites; South Australia requires OCPP 1.6 or an equivalent (2024) | 230/400 V, 50 Hz | National Electric Vehicle Strategy (2023); minimum operating standards for funded sites (2024) | Australia and New Zealand |
| New Zealand | Type 2; Type 1 on Japanese imports | CCS2 and CHAdeMO side by side | PLC; CAN for CHAdeMO | Not confirmed | 230/400 V, 50 Hz | Goal of 10,000 public charge points by 2030; zero interest loans (2025, 2026) | Australia and New Zealand |
| United Arab Emirates | Type 2 | CCS2 (Dubai public equipment); CHAdeMO on older DEWA chargers | PLC | OCPP 1.6J at least (Dubai) | 230/400 V, 50 Hz | Dubai EV Charging Infrastructure Regulation (2024); Cabinet Resolution 81 of 2024 on tariffs | Middle East and Africa |
| Saudi Arabia | Type 2 (verify) | CCS2 (verify) | PLC | Not confirmed | 230/400 V, 60 Hz | MOMRAH technical requirements (1442 H); EVIQ, more than 5,000 fast chargers by 2030 | Middle East and Africa |
| Israel | Type 2 | CCS2 | PLC | Not confirmed | 230/400 V, 50 Hz | Not confirmed | Middle East and Africa |
| Turkey | Type 2 (verify) | CCS2 (verify) | PLC | Not confirmed | 230/400 V, 50 Hz | Charging Service Regulation (2022), EPDK operator licences; amended 2026 | Middle East and Africa |
| South Africa | Type 2 (verify) | CCS2 (verify) | PLC | Not confirmed | 230/400 V, 50 Hz | Not confirmed | Middle East and Africa |
Where a row says PLC, the charger and the car first agree on a protocol in the supportedAppProtocol handshake: DIN SPEC 70121: DC charging, the early CCS protocol, ISO 15118-2: the first generation application layer or ISO 15118-20: the second generation. See The app protocol handshake.
Three families of DC communication
| Family | Physical link | Protocols | Connectors | Where |
|---|---|---|---|---|
| Powerline (PLC) | HomePlug Green PHY on the Control Pilot wire, paired by SLAC (ISO 15118-3: powerline communication and SLAC); IPv6, TCP, optionally TLS | DIN SPEC 70121: DC charging, the early CCS protocol, ISO 15118-2: the first generation application layer, ISO 15118-20: the second generation, all EXI encoded | CCS1, CCS2, J3400 | Europe, North America, Korea, India, Australia and most markets that follow them |
| CAN, CHAdeMO | CAN at 500 kbit/s plus analogue start and enable lines | CHAdeMO: DC charging over CAN | CHAdeMO | Japan, and older cars worldwide |
| CAN, GB/T | CAN at 250 kbit/s with SAE SAE J1939 on a charging bus addressing, plus CC1 and CC2 connection lines and a 12 V auxiliary supply | GB/T 27930: the Chinese DC protocol | GB/T 20234.3 | China |
The families differ below the application layer, so a capture of each looks different. PLC needs a sniffer on the pilot or a network tap behind the modem; a CAN session needs a CAN logger on the communication pair. ChaoJi and CHAdeMO 3.0 keeps CAN but moves to a new, smaller connector; the Megawatt Charging System keeps ISO 15118-20: the second generation but replaces powerline with an Ethernet pair. See How the charging standards fit together and Recording a charging session for analysis.
How adapters bridge them
- Same family, different shape: CCS1 and J3400 share the Control Pilot signalling and the protocols. A CCS1 to J3400 adapter only routes contacts (pilot, proximity, power) and translates nothing. See SAE J3400: the NACS coupler.
- Same family, CAN on both sides: the plan for ChaoJi and CHAdeMO 3.0 is that adapters let a ChaoJi car use existing CHAdeMO or GB/T chargers, because both sides speak closely related CAN protocols.
- Different families: between PLC and CAN a passive adapter cannot work. An active adapter has its own controller and speaks one protocol to the car and the other to the charger. A capture on each side then shows a different conversation, and a fault may lie in the adapter itself.
- Any adapter adds contact resistance and its own temperature limit; a car or charger may limit current when it knows an adapter is present. Reduced power through an adapter is not by itself a protocol fault.
When testing through an adapter, record its make and firmware in the report, and capture on the charger side as well as the car side if you can. See Interoperability test events.
Megawatt charging for trucks
The Megawatt Charging System (MCS: the Megawatt Charging System) is the heavy vehicle connector of the CCS world: IEC TS 63379 and SAE J3271 describe the coupler, and the car to charger link is ISO 15118-20: the second generation over 10BASE-T1S single pair Ethernet in place of powerline. Its session layer is therefore the same as on a CCS2 cable once the Ethernet link is up.
Where MCS chargers are being deployed (European and North American truck corridors) and whether China uses a megawatt standard of its own were not confirmed from a primary source in this review. See Heavy duty trucks and the Megawatt Charging System for the deployment picture.
In this tool
- The tool reads all three families: the PLC protocols from pcap captures (with the IS20 checks for ISO 15118-20), CHAdeMO and GB/T 27930 from CAN frames (with the CAN, CH and GB checks). The demos below show one session of each.
- The format of a file is decided by reading it, not by its name, so a capture from any market opens the same way.
- Two limit profiles ship: the IEC 61851-1 and ISO 15118-2 defaults (230 V nominal) and SAE J1772 and J3400 for North America (240 V). A market with another supply, such as 100 V or 200 V in Japan, needs a copied profile with its own value. See Limit profiles: the numbers behind every check.
- ChaoJi sessions are not decoded yet, and MCS captures are read on the Ethernet pair as ISO 15118-20. See ChaoJi and CHAdeMO 3.0 and MCS: the Megawatt Charging System.
Sources
- O Setor Elétrico, edition 195, ANEEL REN 1.000/2021 revoked REN 819/2018; recharging in Chapter V from article 550
- Regulation (EU) 2023/1804, Alternative Fuels Infrastructure Regulation (AFIR)
- Directive 2014/94/EU, Type 2 and Combo 2 as the common connectors for public points in the EU
- National Electric Vehicle Infrastructure Standards and Requirements, Federal Highway Administration, final rule, Federal Register, 28 February 2023 (23 CFR Part 680)
- 23 CFR Part 680, eCFR, National Electric Vehicle Infrastructure standards
- IEC 62196-2 and IEC 62196-3, AC and DC couplers
- SAE J1772 and SAE J3400, Type 1, CCS1 and the North American Charging System
- GB/T 18487.1, GB/T 20234 and GB/T 27930, 2015 editions
- CHAdeMO specification, connector, signal lines and CAN
- DIN SPEC 70121, ISO 15118-2, ISO 15118-3 and ISO 15118-20, PLC based DC communication
- IEC TS 63379 and SAE J3271, Megawatt Charging System
- OCPP 1.6 and 2.0.1, Open Charge Alliance
- Minimum operating standards for government-supported EV charging infrastructure, DCCEEW, Australia
- Technical Regulator Guideline: Technical Standard for Installation of EVSE, Government of South Australia, V1.11
- Charging point connectors and socket outlets, NZTA national guidance
- Charging ahead: 2,500+ EV chargers on the way, New Zealand Government, March 2026
- Electric Vehicles Charging Infrastructure Regulation for the Emirate of Dubai, DEWA
- Cabinet Resolution No. (81) of 2024, UAE, unified EV charging fee
- Technical requirements for electric vehicles charging (1442 H), MOMRAH, Saudi Arabia
- EVIQ to boost EV charging facilities in Riyadh, Gulf Business, 2025
- Charging connections, Eldan, Israel
- Charging Service Regulation (consolidated English text), EPIAS, Turkey